9
Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour,
PowerChange=2W
MaxTime
MinTime
MinTime MinTime
MinTime MinTime MinTime
0H
15
th
M
30
th
M
45
th
M 1H 1H15
th
M
1H30
th
M
Remarks:
1.
Compare the collected data with the last reported data. If the amount of data change is greater than ReportableChange, the
device will report based on the MinTime interval. If the data change is not greater than the last reported data, the device will
report based on the MaxTime interval.
2.
For the energy consumption detection device, because the device is a constant power supply device, it is not recommended to
set the MinTime interval value too high in order to obtain the status information in real time. It is recommended to use the
default 2 seconds. If users need to control frequent report recommendations to adjust ReportableChange and MaxTime.
3.
After the device sends a packet (regardless of whether the data has changed, such as pressing a button or the maximum time
is due), another MinTime / MaxTime calculation cycle is initiated.
6. Product Installation
This product does not have a waterproof function. After the screening is completed, please place it indoors.
Note:
The energy data of R816B is saved once every 10 seconds if the memory chip is AT24C02, once every 10 seconds for AT2402.
After power off, the data within 10 seconds will be gone.
Collects data
13W
REPORT ON
Collects data
9W
Does not report
Collects data
10W
REPORTS
Collects data
12W
Does not report
Collects data
14W
Does not report
Collects data
13W
Does not report
Collects data
14W
REPORT
Power Change
over 2W