background image

 

 

4.

 

Set up Instruction 

On/Off 

 

 

Power On 

RA0730 and RA0730Y are connected to DC 12V adapter for power on. 

R72630 applies solar and rechargeable lithium batteries. 

 

Turn On 

Connect with power on to turn on 

 

Restore to Factory Setting 

Press and hold the function key for 5 seconds till green indicator flashes for 20 times. 

 

Power Off 

Disconnect from the power supply 

 

*The engineering test requires to write the engineering testing software separately. 

 

Network Joining

 

 

 

Note 

The interval between on and off is suggested to be about 10 seconds to avoid the interference 

of capacitor inductance and other energy storage components. 

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail 

 

Had joined the network 

(Not in the original setting) 

Turn on the device to search the previous network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail. 

 

Fail to Join the Network 

Suggest checking the device registration information on the gateway or consulting your 

platform server provider if the device fails to join the network. 

 

Function Key 

 

 

Press and Hold for 5 Seconds 

Restore to the original setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

 

Press once 

The device is in the network: the green indicator flashes once and the device sends a data 

report 

The device is not in the network: the green indicator remains off 

 

 

 

Low Voltage Threshold 

 

 

Low Voltage Threshold 

10.5 V 

 

Summary of Contents for R72630

Page 1: ...0730_R72630_RA0730Y User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict...

Page 2: ...Set up Instruction 4 5 Data Report 5 6 Installation 7 6 1 The output value of Wind direction corresponds to wind direction 7 6 2 Installation Method of Wind Direction Sensor 7 6 3 Installation 8 6 4 R...

Page 3: ...distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance...

Page 4: ...12V adapters R72630 applies solar and rechargeable lithium batteries Simple operation and setting Wind speed wind direction temperature and humidity detection Adopt SX1276 wireless communication modu...

Page 5: ...search the network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had joined the network Not in the original setting Turn on the device to search the previous...

Page 6: ...ng to the TxPeriod cycle The particular report cycle is ReportMaxTime or TxPeriod depending on which report cycle was configured last time 6 It would take a while for the sensor to sample and process...

Page 7: ...00000 configuration failure 2 Read RA0730 device parameter Downlink 0205000000000000000000 Device return 8205001E0E100000000000 device current parameter Description Device CmdI D Device Type NetvoxPay...

Page 8: ...ed flange connection makes the lower components of the wind direction sensor firmly fixed on the flange plate Four installation holes of 6mm are on the circumference of the chassis The bolts are used...

Page 9: ...all the washer and the nut in sequence Lock nut till the solar panel is stable and does not shake 3 After adjusting the angle of the solar panel completely lock the nut 4 Connect the top waterproof ca...

Page 10: ...9 Range of diameter of post for mounting 25 50 mm...

Page 11: ...000mah The installation of rechargeable lithium battery steps are as follows 1 Remove the four screws around battery cover 2 Insert three 18650 lithium batteries Please make sure the positive and nega...

Page 12: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...