background image

1

Table of Content

1. Introduction.............................................................................................................................................................................................................................................................. 1
2. Appearance...............................................................................................................................................................................................................................................................1
Figure 3 RA0711Y external liquid level sensor (subject to the actual object)............................................................................................................................................................3
3. Main Features...........................................................................................................................................................................................................................................................3
4.Set up Instruction...................................................................................................................................................................................................................................................... 4
5. Data Report.............................................................................................................................................................................................................................................................. 5
6. Installation................................................................................................................................................................................................................................................................7
7. Important Maintenance Instruction..........................................................................................................................................................................................................................9

1.

Introduction

RA0711_R72611_RA0711Y is a ClassA type device based on the LoRaWAN open protocol.
RA0711_R72611_RA0711Y can be connected to the liquid level sensor and report the value collected by the sensor to the corresponding gateway.

LoRa Wireless Technology:
LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods,
LoRa spread spectrum modulation method greatly increases to expand the communication distance. Widely used in long-distance, low-data wireless
communications. For example, automatic meter reading, building automation equipment, wireless security systems, industrial monitoring. Main
features include small size, low power consumption, transmission distance, anti-interference ability and so on.

LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and gateways from different
manufacturers.

2.

Appearance

Figure 1. RA0711 external liquid level sensor (subject to the actual object)

Summary of Contents for R72611

Page 1: ...Model RA0711_R72611_RA0711Y Wireless Liquid Level Sensor Wireless Liquid Level Sensor User Manual Firmware V1 3 Hardware V0 4...

Page 2: ...nology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Wide...

Page 3: ...2 Figure 2 R72611 external liquid level Sensor subject to the actual object...

Page 4: ...ect to the actual object 3 Main Features Compatible with LoRaWAN RA0711 RA0711Y apply DC 12V adapter R72611 applies solar and rechargeable lithium batteries Simple operation and setting Liquid Level d...

Page 5: ...tteries if the device is not used to save power Suggest to check the device verification information on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds R...

Page 6: ...cording to the cycle time of the TxPeriod value and at a certain time the report period is ReportMaxTime or TxPeriod depending on which cycle time is configured last time 3 After pressing the button t...

Page 7: ...Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval Wakes up and collects data...

Page 8: ...e device in a metal enclosure or other electrical equipment around it to avoid affecting the wireless transmission of the device Liquid level transmitter installation precautions The liquid level tran...

Page 9: ...ry to detect the water level 2 The RA72611 product is waterproof After the network joining is completed please leave it outdoors 1 In the position to be installed loosen the U shaped screw of the bott...

Page 10: ...nty service effectively Keep the equipment dry Rain moisture and various liquids or moisture may contain minerals that can corrode electronic circuits In case the device is wet please dry it completel...

Reviews: