4
4.Set up Instruction
On/Off
Power on
RA0711 and RA0711Y
are connected to the DC 12V adapter for power-on;
R72611
applies solar and rechargeable lithium batteries.
Turn on
Power on to turn on.
Restore to factory setting
Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off
Remove power
Note:
1. Engineering test modes require the burning engineering test software.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other
energy storage components.
Network Joining
Never joined the network
(Or at factory setting )
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
(Not at factory setting.)
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
(when the device is on)
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used to save power.
Suggest to check the device verification information on the gateway
or consult your platform server provider.
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: the green indicator flashes once and the device sends a data report
The device is not in the network: green indicator remains off
Low Voltage Threshold
Low Voltage Threshold
10.5 V
Restore to Factory Setting
Instruction
RA0711_R72611_RA0711Y has a network information memory function saving function when power-down. This
finction is turned off by default, that is, it will be re-joined every time it is powered back on. This function can be
turned on by the ResumeNetOnOff command. At this time, each time the power is rewritten, the last network
joining information will be recorded (including saving the network address information assigned to it, etc., if you
want to join a new network, you need to perform a factory resetting operation first.) It will not be re-joined the
previous network.
Operation
1. Press and hold the button for 5 seconds and release (the binding button is released when the LED flashes), and
the LED flashes for 20 times.
2. The device will automatically restart to re-joining.