5. Data Report

The device will immediately send a version package Report and a report data with temperature and humidity and voltage
Values. The device sends data in the default configuration before any configuration is done.

ReportMaxTime:

RA0711_ RA0711Y

is 180s and RA72611 is 900s; (subject to factory settings)

ReportMinTime: 30s;
ReportChange: 0;

Note: The device send data cycle has been programmed to be correct.
The interval between two reports must be the maximum time
The RA0711_R72611_RA0711Y device does not support the ReportChange function, that is, the function is invalid.
The sent report data string is always sent according to the ReportMaxTime period
(starting to the end of the first data as a period).
The data of the device Report is: lequid level value, ReportType count = 1;

Note: 1. The value of ReportMaxTime is greater than (ReportType count *ReportM 10 units: seconds);
2. The device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, the device can also perform a

report according to the cycle time of the TxPeriod value; and at a certain time, the report period is ReportMaxTime or
TxPeriod, depending on which cycle time is configured last time;

3. After pressing the button, the device needs 35 seconds to process the sensor information, please be patient.

The data parsing reported by the device is referenced by the Netvox LoraWAN Application Command document and

http://www.netvox.com.cn:8888/page/index

Report Configuration Example:

(1) Configure RA0711 device parameters MinTime = 30s, MaxTime = 120s (120>30*1+10)

Downlink: 0105001E00780000000000
Device returns:

8105000000000000000000 (configuration is successful)
8105010000000000000000 (configuration failed)

(2) Read RA0711 device parameters

Downlink: 0205000000000000000000
Device returns:

8205001E00780000000000 (device current parameter)

Description

Device

CmdID

DeviceTy

pe

NetvoxPayLoadData

ConfigReportRe

q

RA07

Series/

R726

Series/

R727

Series

0x01

0x05/0x0

9/0x0D

MinTime(2

bytes

Unit:s)

MaxTime(2by

tes Unit:s)

Reserved

(5Bytes,Fixed 0x00)

ConfigReportRs

p

0x81

Status(0x00

_success)

Reserved (8Bytes,Fixed 0x00)

ReadConfigRepo

rtReq

0x02

Reserved (9Bytes,Fixed 0x00)

ReadConfigRepo

rtRsp

0x82

MinTime(2

bytes

Unit:s)

MaxTime(2by

tes Unit:s)

Reserved

Summary of Contents for R72611

Page 1: ...Model RA0711_R72611_RA0711Y Wireless Liquid Level Sensor Wireless Liquid Level Sensor User Manual Firmware V1 3 Hardware V0 4...

Page 2: ...nology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Wide...

Page 3: ...2 Figure 2 R72611 external liquid level Sensor subject to the actual object...

Page 4: ...ect to the actual object 3 Main Features Compatible with LoRaWAN RA0711 RA0711Y apply DC 12V adapter R72611 applies solar and rechargeable lithium batteries Simple operation and setting Liquid Level d...

Page 5: ...tteries if the device is not used to save power Suggest to check the device verification information on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds R...

Page 6: ...cording to the cycle time of the TxPeriod value and at a certain time the report period is ReportMaxTime or TxPeriod depending on which cycle time is configured last time 3 After pressing the button t...

Page 7: ...Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval Wakes up and collects data...

Page 8: ...e device in a metal enclosure or other electrical equipment around it to avoid affecting the wireless transmission of the device Liquid level transmitter installation precautions The liquid level tran...

Page 9: ...ry to detect the water level 2 The RA72611 product is waterproof After the network joining is completed please leave it outdoors 1 In the position to be installed loosen the U shaped screw of the bott...

Page 10: ...nty service effectively Keep the equipment dry Rain moisture and various liquids or moisture may contain minerals that can corrode electronic circuits In case the device is wet please dry it completel...