background image

8

Remarks: Liquid level transmitter installation details, please refer to the documentation

CYW11通用型投入式液位变送器.pdf

Installation

Cable hanger installation

Cable fixing flange installation

Liquid level transmitter use precautions

The level transmitter is made of stainless steel and is not allowed to be used in media that are not compatible with stainless steel.

Before the liquid level transmitter is powered on, ensure that the power supply voltage meets the power supply requirements of the liquid level
transmitter, the positive and negative terminals are connected correctly, and the highest liquid level is within the range of the liquid level
transmitter.

When using, try to avoid the water level transmitter cable terminal immersing in water, the water will damage the liquid level transmitter.

When using, try to avoid sharp objects damage to the liquid level transmitter. Damage will cause the water inlet to damage the liquid level
transmitter.

The liquid level transmitter is a precision instrument and is not allowed to be disassembled to avoid damage.

The level detector (RA0711) is suitable for the following scenarios

Water tank

Pool

River water level measurement

When it is necessary to detect the water level.

2. The RA72611 product is waterproof. After the network-joining is completed, please leave it outdoors.

(1) In the position to be installed, loosen the U-shaped screw of the bottom of the RA72611 and the mating washer nut, and fix the U-shaped screw
through the appropriate size cylinder on the RA72611 fixed strut piece. Install the washer nut in order, lock the nut till RA72611 body is stable and
does not shake.
(2) At the upper side of the fixed position of RA72611, loosen the two U-shaped screws on the side of the solar panel and the mating washer nut. Fix
the U-shaped screw through the appropriate size cylinder on the main bracket of the solar panel, and install the gasket in sequence. Lock nut till the
solar panel is stable and does not shake.
(3) Adjust the angle of the solar panel. After the adjustment is completed, lock the nut.
(4) Connect the RA72611 top waterproof cable to the solar panel wiring and lock it tight.

(5) R726X has a battery compartment inside, users can buy and install rechargeable 18650 lithium battery, a total of 3 sections, a single rechargeable
lithium battery voltage 3.7V, capacity recommended 5000mah, the installation of rechargeable lithium battery steps are as follows:
1: Remove the four battery box screws and install three rechargeable lithium batteries.
2: Press the activation button on the battery box for the first time.

Summary of Contents for R72611

Page 1: ...Model RA0711_R72611_RA0711Y Wireless Liquid Level Sensor Wireless Liquid Level Sensor User Manual Firmware V1 3 Hardware V0 4...

Page 2: ...nology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Wide...

Page 3: ...2 Figure 2 R72611 external liquid level Sensor subject to the actual object...

Page 4: ...ect to the actual object 3 Main Features Compatible with LoRaWAN RA0711 RA0711Y apply DC 12V adapter R72611 applies solar and rechargeable lithium batteries Simple operation and setting Liquid Level d...

Page 5: ...tteries if the device is not used to save power Suggest to check the device verification information on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds R...

Page 6: ...cording to the cycle time of the TxPeriod value and at a certain time the report period is ReportMaxTime or TxPeriod depending on which cycle time is configured last time 3 After pressing the button t...

Page 7: ...Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval Wakes up and collects data...

Page 8: ...e device in a metal enclosure or other electrical equipment around it to avoid affecting the wireless transmission of the device Liquid level transmitter installation precautions The liquid level tran...

Page 9: ...ry to detect the water level 2 The RA72611 product is waterproof After the network joining is completed please leave it outdoors 1 In the position to be installed loosen the U shaped screw of the bott...

Page 10: ...nty service effectively Keep the equipment dry Rain moisture and various liquids or moisture may contain minerals that can corrode electronic circuits In case the device is wet please dry it completel...

Reviews: