5
5. Data Report
The device will immediately send a version package Report and a report data with temperature and humidity and voltage
Values. The device sends data in the default configuration before any configuration is done.
ReportMaxTime:
RA0711_ RA0711Y
is 180s and RA72611 is 900s; (subject to factory settings)
ReportMinTime: 30s;
ReportChange: 0;
Note: The device send data cycle has been programmed to be correct.
The interval between two reports must be the maximum time
The RA0711_R72611_RA0711Y device does not support the ReportChange function, that is, the function is invalid.
The sent report data string is always sent according to the ReportMaxTime period
(starting to the end of the first data as a period).
The data of the device Report is: lequid level value, ReportType count = 1;
Note: 1. The value of ReportMaxTime is greater than (ReportType count *ReportM 10 units: seconds);
2. The device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, the device can also perform a
report according to the cycle time of the TxPeriod value; and at a certain time, the report period is ReportMaxTime or
TxPeriod, depending on which cycle time is configured last time;
3. After pressing the button, the device needs 35 seconds to process the sensor information, please be patient.
The data parsing reported by the device is referenced by the Netvox LoraWAN Application Command document and
http://www.netvox.com.cn:8888/page/index
Report Configuration Example:
(1) Configure RA0711 device parameters MinTime = 30s, MaxTime = 120s (120>30*1+10)
Downlink: 0105001E00780000000000
Device returns:
8105000000000000000000 (configuration is successful)
8105010000000000000000 (configuration failed)
(2) Read RA0711 device parameters
Downlink: 0205000000000000000000
Device returns:
8205001E00780000000000 (device current parameter)
Description
Device
CmdID
DeviceTy
pe
NetvoxPayLoadData
ConfigReportRe
q
RA07
Series/
R726
Series/
R727
Series
0x01
0x05/0x0
9/0x0D
MinTime(2
bytes
Unit:s)
MaxTime(2by
tes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
ConfigReportRs
p
0x81
Status(0x00
_success)
Reserved (8Bytes,Fixed 0x00)
ReadConfigRepo
rtReq
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfigRepo
rtRsp
0x82
MinTime(2
bytes
Unit:s)
MaxTime(2by
tes Unit:s)
Reserved