5. Data Report 

 

5.1 Example of ReportDataCmd 

FPort

0x06 

 

Bytes 

Var(Fix=8 Bytes) 

 

Version 

DeviceType 

ReportType 

NetvoxPayLoadData 

Version

– 1 byte –0x01

——

the Version of NetvoxLoRaWAN Application Command Version 

DeviceType

– 1 byte – Device Type of Device 

 

 

 

 

   

The devicetype is listed in Netvox LoRaWAN Application Devicetype doc 

ReportType

 – 1 byte –the presentation of the NetvoxPayLoadData

according the devicetype 

NetvoxPayLoadData

– Fixed bytes (Fixed =8bytes) 

After power on, the device will immediately send a version packet report and an attribute packet report. 

The device sends data according to the default configuration before any other configuring. 

Default Setting 

Maximum time: 900s (15min) 

Minimum time:900s (15min) 

Battery Voltage Change - 0x01 (Unit:0.1v, 0.1V) 

Distance Change - 0x012C (Unit:1mm, 300mm) 

 

Data packet: 

a.

 

When used in

 

level / material level detection:   

R718PE01 reports Battery voltage, Distance, Fill Level ; Status=0 (Invalid) 

b.

 

When used in parking detection:   

R718PE01 reports Battery voltage, Status, Distance ; Fill Level=0 (Invalid) 

   

Note:   

1.

 

The cycle of the device sending the data report is according to the default. 

2.

 

The interval between two reports must be the MinTime. 

Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver   

http://www.netvox.com.cn:8888/page/index to resolve uplink data.

 

Summary of Contents for R718PE01

Page 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Page 2: ...ing Mode 8 5 4 Example of DeadZoneDistance 9 5 5 Example of General Calibration Configuration 10 5 6 Example for MinTime MaxTime logic 11 6 Application 13 7 Installation 14 8 Comparison between R718PE...

Page 3: ...communication module The device is compatible with LoRaWAN protocol LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared...

Page 4: ...ible with LoRaWANTM Class A Frequency hopping spread spectrum technology Configuration parameters can be configured through third party software platforms data can be read and alarms can be set via SM...

Page 5: ...een indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indi...

Page 6: ...device sends data according to the default configuration before any other configuring Default Setting Maximum time 900s 15min Minimum time 900s 15min Battery Voltage Change 0x01 Unit 0 1v 0 1V Distan...

Page 7: ...0190 HEX 400 DEC 400 1mm 400mm 8th 14 FillLevel 20 14 HEX 20 DEC 20 1 20 9th 11th 000000 Reserved 5 2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData Cm...

Page 8: ...0 SetFillMax DistanceRsp 0x85 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetFillMax DistanceReq 0x06 Reserved 9Bytes Fixed 0x00 GetFillMax DistanceRsp 0x86 FillMaxDistance 2byte Unit 1mm Reserved...

Page 9: ...0000000000000000 Device returns 86B1138800000000000000 device current parameter 5 3 Example of Switching Mode Switching mode is achieved by setting the values of FillMaxDistance and OnDistanceThreshol...

Page 10: ...0000000000000 Device returns 83B1000000000000000000 4 Read OnDistanceThreshold confirm whether it has been set successfully Downlink 04B1000000000000000000 Device returns 83B101F400000000000000 5 4 Ex...

Page 11: ...l 1Byte 0_Channel1 1_Channel2 etc Multiplier 2bytes Unsigned Divisor 2bytes Unsigned DeltValue 2bytes Signed Reserved 2Bytes Fixed 0x00 ClearGlobal CalibrateReq 0x03 Reserved 10Bytes Fixed 0x00 ClearG...

Page 12: ...Device returns 8300000000000000000000 Note 1 When Multiplier is not 1 Calibration value DeltValue Multiplier 2 When Divisor is not 1 Calibration value DeltValue Divisor 3 This universal calibration s...

Page 13: ...henever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started MaxTime Sleeping MinTime sleeping sl...

Page 14: ...aterial level in the barn The value of the total height of the barn can be set through commands according to the specific scene Illustration 1 Illustration 2 FillLevel H D H 100 FillLevel H D H d 100...

Page 15: ...e the data returned by the device is the position distance value that meets the detection requirements of the ultrasonic sensor within the measurement range In addition the following formula can be us...

Page 16: ...Installation precautions 1 The installation position of the ultrasonic probe is required to be perpendicular to the center of the plane of the measured object When the plane of the measured object is...

Page 17: ...operation and our devices may not work correctly in this situation As a result please make sure to source batteries from reliable vendors and it is suggested that if the storage period is more than o...

Page 18: ...o normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy internal circuit boards and delicate structure...