2.

 

Appearance 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

 

Main Feature 

 

Adopt SX1276 wireless communication module   

 

RS485 communication   

 

12V DC power supply 

 

Detecting the turbidity value and the temperature of the solution 

 

The base is attached with a magnet that can be attached to a ferromagnetic material object 

 

Main body protection level IP65 / IP67 (Optional) 

 

Compatible with LoRaWAN

TM

 Class A 

 

Frequency hopping spread spectrum technology 

 

Configuring  parameters  and  reading  data  via  the  third-party  software  platforms,  and  set  alarms  via  SMS  text  and  email 

(optional) 

 

Applicable to the third-party platforms: Actility/ ThingPark/ TTN/ MyDevices/ Cayenn 

Note:   

Battery life is determined by the sensor reporting frequency and other variables, please refer to 

http://www.netvox.com.tw/electric/electric_calc.html 

                                                                       

On this website, users can find battery lifetime for varied models at different configurations. 

 

 

 

Turbidity Sensor 

Indicator 

Function Key 

Summary of Contents for R718PA Series

Page 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 9...

Page 3: ...low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wir...

Page 4: ...ass A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third...

Page 5: ...The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not restore to the factory setting Turn on the device to search the previous network The...

Page 6: ...ex Example of ReportDataCmd FPort 0x06 Bytes 1 1 1 Var Fix 8 Bytes Version DeviceType ReportType NetvoxPayLoadData Version 1 byte 0x01 the Version of NetvoxLoRaWAN Application Command Version DeviceTy...

Page 7: ...157000000000000000000 configuration success 8157010000000000000000 configuration failure 1 Read R718PA10 device parameter Downlink 0257000000000000000000 Device Return 8257000A003C0000000000 device cu...

Page 8: ...or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA10 regularly reports the data of the turbidity value and the temperatu...

Page 9: ...ntenance Method 1 External Surface of The Sensor Use tap water to clean the external surface of the sensor If there are still debris remaining wipe it with a moistened soft cloth For some stubborn dir...

Page 10: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...