background image

 

 

6.

 

Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. R718PA10 has the built-in magnet (as the figure below) 

which can be attached to the surface of an iron object 

during installation, which is convenient and quick. 

In order to make the installation firmer, please use screws 

(purchased separately) to fix the device to the wall or other 

surface (as Figure below). 

Note:   

Do not install the device in a metal shielded box or in an 

environment surrounded by other electrical equipment to 

avoid affecting the wireless transmission of the device. 

 

2. R718PA10 regularly reports the data of the turbidity value 

and the temperature of the solution according to MaxTime. 

The default Max Time is 3 minutes. 

 

Note: 

MaxTime can be modified by the downlink command, but it 

is recommended not to set the interval too short. 

R718PA10 can be applied to detecting the turbidity and the 

temperature of the solution. 

Example: 

 

Water Quality Monitor 

Screw 

Fixation 

 

Screw 

Fixation 

 

Turbidity Sensor 

R718PA10 

Socket 

Adapter 12V 

Summary of Contents for R718PA Series

Page 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 9...

Page 3: ...low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wir...

Page 4: ...ass A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third...

Page 5: ...The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not restore to the factory setting Turn on the device to search the previous network The...

Page 6: ...ex Example of ReportDataCmd FPort 0x06 Bytes 1 1 1 Var Fix 8 Bytes Version DeviceType ReportType NetvoxPayLoadData Version 1 byte 0x01 the Version of NetvoxLoRaWAN Application Command Version DeviceTy...

Page 7: ...157000000000000000000 configuration success 8157010000000000000000 configuration failure 1 Read R718PA10 device parameter Downlink 0257000000000000000000 Device Return 8257000A003C0000000000 device cu...

Page 8: ...or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA10 regularly reports the data of the turbidity value and the temperatu...

Page 9: ...ntenance Method 1 External Surface of The Sensor Use tap water to clean the external surface of the sensor If there are still debris remaining wipe it with a moistened soft cloth For some stubborn dir...

Page 10: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: