4
4.
Set up Instruction
On/Off
Power on
Insert batteries. (users may need a flat blade screwdriver to open)
Turn on
Press and hold the function key for 3 seconds till the green indicator flashes once.
Turn off
(Restore to factory setting)
Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off
Remove Batteries.
Note
1.The device will be off after removing the battery and insert it again.
2.It is suggested to wait for at least 10 seconds between turning the device on and off.
3.At 1
st
-5
th
second after power on, the device will be in engineering test mode.
Network Joining
If the device has never joined the
network
Turn on the device, and it will search for the network to join.
The green indicator light stays on for 5 seconds: joins the network successfully
The green indicator light remains off: fail to join the network
If the device has joined the network
and it is not set to default
Turn on the device, and it will search for the previous network to join.
The green indicator light stays on for 5 seconds: joins the network successfully
The green indicator light remains off: fail to join the network
If the device fails to join the network
(when the device is turned on)
For the first two minutes: the device will wake up every 15 seconds to send a join request.
After two minutes: the device will enter sleep mode and wake up every 15 minutes to send a join request.
Note: It is suggested to remove the batteries if the device is not in use to save power.
It is suggested to check the device verification information on the gateway
or consult your platform server provider when the device fails to join the network.
Function Key
Press the function key and hold the
pressing for 5 seconds
The device will be set to default and turned off
The green indicator light flashes for 20 times: success
The green indicator light remains off: fail
Press the function key once
The device is in the network: green indicator light flashes once and sends a report
The device is not in the network: green indicator light remains off
Sleeping Mode
The device is turned on and in the
network
Sleep period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according to Min
Interval.
The device is turned on but not in
the network
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used.
Suggest to check device verification on gateway.
Low Voltage Warning
Low Voltage
3.2 V