background image

 

 

Example of Report configuration

 

FPort

0x07 

Bytes 

Var(Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 bytes   

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

 

 

(1)

 

Command Configuration:

 

  MinTime = 1min

MaxTime = 1min

BatteryChange = 0.1v 

     Downlink

  0125003C003C0100000000      003C(H

ex) 

= 60(D

ec) 

   

     Response

 

            

    

8125000000000000000000

Configuration success

 

            

    

8125010000000000000000

Configuration failure

 

 

(2)

 

Read Configuration:

 

     

Downlink

  0225000000000000000000 

     Response

 

            

      

8225003C003C0100000000

Current configuration

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description 

Device 

CmdID 

Device 

Type 

NetvoxPayLoadData 

Config 

ReportReq 

R718LB 

0x01 

0x25 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Battery 

Change 

(1byte Unit:0.1v) 

Reserved 

(4Bytes,Fixed 0x00) 

Config 

ReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

  (8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

  (9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Battery 

Change 

(1byte Unit:0.1v) 

Reserved 

(4Bytes,Fixed 0x00) 

Summary of Contents for R718LB

Page 1: ...vox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to othe...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 6 6 Installation 9 7 Important Maintenance Instruction 10...

Page 3: ...rum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equip...

Page 4: ...onfigurable parameters via third party software platform reading data and setting alarms via SMS text and email optional Available for third party platforms Actility ThingPark TTN MyDevices Cayenne Im...

Page 5: ...icator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator s...

Page 6: ...ta report according to Min Interval The device is on but not in the network First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to s...

Page 7: ...uration is done Default setting MaxTime Max Interval 60 min 3600s MinTime Min Interval 60 min 3600s BatteryChange 0x01 0 1V Hall sensor status When the magnet closes to the Hall sensor it will report...

Page 8: ...00000000000 Configuration failure 2 Read Configuration Downlink 0225000000000000000000 Response 8225003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Conf...

Page 9: ...er than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up f...

Page 10: ...elded box or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 Tear off 3M release paper of Hall sensor and the magnet then attach...

Page 11: ...rode electronic circuits If the device gets wet please dry it completely Do not use or store the device in dusty or dirty environment It might damage its detachable parts and electronic components Do...

Reviews: