6
5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report along with an uplink packet including hall sensor status and battery
voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime : Max Interval = 60 min = 3600s
MinTime : Min Interval = 60 min = 3600s
BatteryChange: 0x01 (0.1V)
Hall sensor status:
When the magnet closes to the Hall sensor, it will report the status “0”
*The distance between the magnet and the Hall sensor is less than 3cm
When the magnet removes the Hall sensor, it will report the status “1”
*The distance between the magnet and the Hall sensor is greater than 3 cm
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver