Example of Report configuration
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID DeviceType
NetvoxPayLoadData
CmdID
– 1 bytes
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
Description
Device CmdID
DeviceType
NetvoxPayLoadData
ConfigReportReq
R718G
0x01
0x1E
MinTime
(2bytes Unit:s)
MaxTime
(2bytes
Unit:s)
Battery
Change
(1byte
Unit:0.1v)
Illuminancechange
(4bytes Unit
:
1Lux)
ConfigReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes
Unit:s)
Battery
Change
(1byte
Unit:0.1v)
Illuminancechange
(4bytes Unit
:
1Lux)
SetSunlight
SampleRangeReq
0x03
RangeSetting (1byte)
0x00:3~65000 Lux
0x01:3~130000 Lux
0x02:3-220000 Lux
Reserved
(8Bytes,Fixed 0x00)
SetSunlight
SampleRangeRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
GetSunlight
SampleRangeReq
0x04
Reserved
(9Bytes,Fixed 0x00)
GetSunlight
SampleRangeRsp
0x84
RangeSetting (1byte)
0x00:3~65000 Lux
0x01:3~130000 Lux
0x02:3-220000 Lux
Reserved
(8Bytes,Fixed 0x00)