background image

 

 

5. Data Report   

 

 

Data report configuration and sending period are as following: 

 

 

5.1 Example of ReportDataCmd 

FPort

0x06 

Bytes 

Var(Fix=8 Bytes) 

 

Version 

DeviceType 

ReportType 

NetvoxPayLoadData 

Version

– 1 byte –0x01

——

the Version of NetvoxLoRaWAN Application Command Version 

DeviceType

– 1 byte – Device Type of Device 

 

 

 

 

   

The devicetype is listed in Netvox LoRaWAN Application Devicetype doc 

ReportType

 – 1 byte –the presentation of the NetvoxPayLoadData

according the devicetype 

NetvoxPayLoadData

– Fixed bytes (Fixed =8bytes) 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change

≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

The device will immediately send a version packet report along with an uplink packet including temperature, humidity and 

battery voltage. 

The device sends data in the default configuration before any configuration is done. 

Default setting: 

MaxTime: Max Interval = 15 min = 900s 

MinTime: Min Interval = 15 min = 900s 

BatteryChange: 0x01 (0.1V) 

TemperatureChange:0x0064 (1°C) 

HumidityChange:0x0064 (1%) 

Note:   

The device report interval will be programmed based on the default firmware which may vary. 

The interval between two reports must be the minimum time. 

 

Please refer Netvox 

LoRaWAN Application Command document

 and 

Netvox Lora Command Resolver

 

http://www.netvox.com.cn:8888/page/index

 to resolve uplink data.

 

Summary of Contents for R718AB

Page 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Page 2: ...eport 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 6 Installation 9 7 Information about Battery Passivation 11 7 1 To determine whether a batt...

Page 3: ...reatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security...

Page 4: ...oftware platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longe...

Page 5: ...etwork Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on th...

Page 6: ...nge Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval The device will immediately send a version packet report along...

Page 7: ...yte 000000 Reserved Example of Uplink 01130124FF391A9E000000 1st byte 01 Version 2nd byte 13 DeviceType 0x13 R718AB 3rd byte 01 ReportType 4th byte 24 Battery 24 HEX 36 DEC 36 0 1v 3 6v 5th 6th byte F...

Page 8: ...me Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R7...

Page 9: ...ecommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter...

Page 10: ...nsmission of the device The figure shows the scene where the temperature and humidity sensor R718AB is applied in the refrigerator It can also be applied to the following scenarios Restaurant refriger...

Page 11: ...ut the lid back on and tighten the four screws Note Please do not disassemble the device unless it is required to replace the batteries Do not touch the waterproof gasket LED indicator light function...

Page 12: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Page 13: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: