9
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H
15
th
M 30
th
M 45
th
M
1H
2H
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V
MaxTime
sleeping sleeping
0H
15
th
M
30
th
M
45
th
M 1H
1H 10
th
M
1H 25
th
M
Notes:
(1)
The device only wakes up and performs data sampling according to MinTime Interval. When it is in sleeping mode, it does
not collect data.
The collected data is compared with the last reported data. If the variation of the data is greater than the value of
ReportableChange, the device will report according to MinTime interval. If the data variation is not greater than the last
reported data, the device will report according to MaxTime interval.
(2)
We do not recommend setting the MinTime Interval value too low. If the MinTime Interval is too low, the device will wake
up frequently and the battery will be drained soon.
(3)
When the device sends a report, no matter the data changes, button is pushed or MaxTime interval comes, another cycle of
MinTime / MaxTime calculation starts.
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wakes up and collects
data
2.7V |2.7-2.8|=0.1
REPORTS 2.7V
Wakes up and
collects data 2.7V
Does not report
Users push the button,
REPORTS 2.7V.
Recalculate MaxTime.
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
REPORT 2.7V