12
6
Installation
IMPORTANT
Observe the safety instructions in Ch. Safety, page 5.
For operation of the NTP a 3/2-way valve is provided,
•
to ensure a faultless start in any installation position.
•
in order to achieve an immediate standstill when switched off.
Use a maintenance unit for all installations.
The maintenance unit should consist of a filter, a regulator and a mist lu-
bricator (see Ch. Technical data, page 7; "Drive medium"), the NTP L a
filter und regulator.
Connect the NTP with a pneumatic hose according to the following pneu-
matic circuit diagram shown.
1
Maintenance unit
(NTP L: without mist lubricator)
2
3/2-way valve
Special circuit diagrams are available on request.
Information regarding tightening torques for screws as well as cross sec-
tions for valves and hoses can be found in Ch. Technical data, page 7.
Depending on the type of NTP,
Netter
Vibration
supplies suitable fas-
tening sets for tapped holes (NBS G) and through-holes (NBS D) for se-
cure and permanent attachment of the NTP on the weld-on console.
When installing the NTP carry out the following steps in succession:
1. Mount the NTP with the fastening screws on a clean and even surface
(± 0,1 mm) without paint residues or burn-ins. The NTP must be fully in
contact with the surface so that no tension in the housing occurs when
tightening the fastening screws, which could cause mechanical dam-
age.
Safety
instructions
Operation with
3/2-way valve
Components
for all
installations
Standard
installation
Technical data
NBS fastening
kits
Procedure