background image

  NS-280FX

 

: 8x SFP Slots with 2 Giga unmanaged Ethernet switch Ver.A.3

 

 

16 

Appendix B:

 Product Specification 

 

Key

 

Features and Benefits: 

 

 

Supports 2 x 10/100/1000BASE-T & auto–MDIX for RJ-45 port 

 

Supports 8 x 1.25G SFP Slots   

 

Cost effective bridge function for FTTdp/FTTC application 

 

Compatible to VDSL2 SFP module 

 

Support per SFP slot power source up to 3W 

 

Special design for VDSL2/G.fast-SFP module heat dissipation 

 

Supports isolation mode by Slide switch 

 

Compact in size, easy installation 

 

Plug & Play 

 

Flexible application & installation 

 

Support MTU 1632 bytes 

 

Supports 19” Rack mount bracket 

 

 
 
 
 
 
 

Summary of Contents for NS-280FX

Page 1: ... FP P P S S Sl l lo o ot t ts s s w w wi i it t th h h 2 2 2 G G Gi i ig g ga a a u u un n nm m ma a an n na a ag g ge e ed d d E E Et t th h he e er r rn n ne e et t t s s sw w wi i it t tc c ch h h U U US S SE E ER R R S S S M M MA A AN N NU U UA A AL L L ...

Page 2: ...rty rights of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products described in this document without notice NETSYS does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Maximum signal rate deriv...

Page 3: ...ation as NS 280FX s SFP slots are separated to each other and build in two internal fans to prevent SFP module overheat issue With high performance and easy installation NS 280FX can be utilized in ISP network solution for FTTdp Fiber to the distribution point FTTC Fiber to the Curb and FTTB Fiber to the Building also for SOHO application Attention Be sure to read this manual carefully before usin...

Page 4: ...a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO NOT use this product near water for example in a wet basement or near a swimming pool Connect ONLY suitable accessories to the device Make sure to connect the cables to the correct ports DO NOT obstruct the device ventilation slots as insufficient airflow ma...

Page 5: ...7 1 1 Check List 7 Chapter 2 Installing the Device 8 2 1 Hardware Installation 8 2 2 Pre installation Requirements 8 2 3 Connecting the Ethernet of RJ 45 Ports 9 2 4 Connecting the SFP Slot 9 2 5 Application Diagram 10 Chapter 3 Hardware Description 11 3 1 Front panel 11 3 2 LED Indicators 13 Appendix A Cable Requirements 14 Appendix B Product Specification 16 ...

Page 6: ...P Slots with 2 Giga unmanaged Ethernet switch Ver A 3 6 Appendix C Mounting the Switch on a Rack 18 Appendix D Troubleshooting 19 Appendix E Compliance and Safety Information 22 Warranty 25 Chinese SJ T 11364 2014 26 ...

Page 7: ...maged parts If possible retain the carton including the original packing materials Use them to repack the unit in case there is a need to return for repair 2 If the product has any issue please contact your local vendor 3 Please make sure power source is compliant with required specification 4 NS 280FX is a commercial grade product Do not use in industrial grade applications 5 Please look for the ...

Page 8: ...e the right operating environment including power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements AC 100 240 volts 50 60 Hz The device should be located in a cool dry place with at least 10cm 4in of space at the front and back for ventilation Place NS 280FX away from direct sunl...

Page 9: ...to these ports must support auto negotiation or 10Base T 100Base T or 1000Base T and note they don t support half duplex Use any of the Ethernet ports to connect to devices such as Monitor system Server Backbone switch or IP gateway 2 4 Connecting the SFP Slot There are multiple types of SFP module in market please make sure the SFP module support 1 25G Serdes mode otherwise the connection can t s...

Page 10: ...ur Network system which makes NS 280FX meet user s requirement and offer you a variety of combination with other networking devices With 8 SFP slots and suitable SFP transceiver NS 280FX is able to be considered as an IPDSLAM and would perfectly fit in Fiber XDSL networking system NS 280FX also enable user to segment their SFP network and set up multiple isolated network at your premises such as y...

Page 11: ...rear panel 3 1 Front Panel The front panel shown as interface with 8 x SFP Slots 2 x RJ 45 Connector Slide switch for Isolation function and LED indicators 3 1 1 Front panel indicator There are 16 LED indicators on front panel the following Table shows the description Figure 3 1 Front Panel Tip With only a glance of the front panel s LED indicators the converter status will be fully aware ...

Page 12: ...r small form factor pluggable transceiver Isolation Slide switch For enabling disabling SFP port Isolation function Reminder Please use SFP transceiver which is compatible to 1000Base X SFP slot otherwise the connection cannot set up 3 1 2 Slide switch For setting SFP port isolation mode To activate Isolation function slide the switch to ON 3 1 3 Rear Panel The rear panel provides AC Power Jack an...

Page 13: ...transceiver SFP LED indicator will light up right away when the SFP transceiver is inserted into SFP slot LEDs Color Status Description PWR Green ON Power ON OFF Power OFF E1 E2 Ethernet LNK ACT 10M 100M 1G Green ON Steady 10 100 1G Ethernet Link established Blinking The device is sending or receiving data OFF No Connection ISO Isolation Green ON SFP slots Isolation mode OFF SFP slots Un Isolation...

Page 14: ...all of which are used for transmission The connector at the end of the 1000TX cable is referred to as a RJ 45 connector and it consists of eight pins The Ethernet standard uses pins 1 2 3 4 5 and 6 for data transmission purposes Table A 1 1000TX Table A 1 RJ 45 Ethernet Connector Pin Assignments PIN 10 100TX 1000TX Figure A 1 Standard RJ 45 repectacle connector Signal Media Dependant interface Sig...

Page 15: ...0FX 8x SFP Slots with 2 Giga unmanaged Ethernet switch Ver A 3 15 Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable Figure A 3 Pin Assignments and Wiring for an RJ 45 Crossover Cable ...

Page 16: ...pports 8 x 1 25G SFP Slots Cost effective bridge function for FTTdp FTTC application Compatible to VDSL2 SFP module Support per SFP slot power source up to 3W Special design for VDSL2 G fast SFP module heat dissipation Supports isolation mode by Slide switch Compact in size easy installation Plug Play Flexible application installation Support MTU 1632 bytes Supports 19 Rack mount bracket ...

Page 17: ...er Modes SFP ports Isolation function Interface 2 x RJ 45 8 x SFP slot 1 x slide switch LED Indication System PWR Isolation mode ISO Giga port 1G ACT 100M ACT 10M ACT SFP PORT LNK Certification CE FCC RoHS Compliant Temperature 0 C 50 C 32 F 122 F Operating 20 C 70 C 4 F 158 F Storage accessories Rack mount bracket Humidity 10 90 non condensing Weight 1 645 kg Dimensions 356mm x 156mm x 44mm 14 x ...

Page 18: ...g bracket on one side of the rack lining up the two screw holes on the bracket with the screw holes on the side of the rack as figure below 2 Using a screwdriver install the M5 flat head screws through the mounting bracket holes into the rack 3 Repeat steps 1 and 2 to attach the second mounting bracket on the other side of the rack ...

Page 19: ...operly Check the power cord with another device If these measures fail to resolve the problem have the unit sent back to a qualified distributor 2 Symptom Link indicator does not light up green after making a connection Cause Network interface ex a network adapter card on the attached device network cable or SFP transceiver defective Solution Verify if both of the NS 280FX all devices and attached...

Page 20: ...u still cannot isolate the problem then the internal power supply may be defective In this case please contact your local dealer Installation Verify that all system components have been properly installed If one or more components appear to be malfunctioning e g the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning ...

Page 21: ...cable distances and other physical aspects of the installation do not exceed recommendations System Integrity As a last resort verify the switch integrity with a power on reset Turn the power to the switch off and then on several times If the problem still persists and you have completed all the preceding diagnoses then contact your dealer ...

Page 22: ...ning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 The equipment and the receiver should be connected to outlets on separate circuits 4 Consult the dealer or an experienced radio television technician for help Chan...

Page 23: ...The direct plug in wall transformer serves as the main product for disconnecting The socket outlet shall be installed near the product and be readily accessible Do not use this equipment near water for example in a wet basement Avoid using a telephone during an electrical storm There may be a remote risk of electrical shock from lightning Do not use the telephone to report a gas leak in the vicini...

Page 24: ... the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at owner s expense CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be requ...

Page 25: ...ential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Warranty The original owner that the product deli...

Page 26: ... not be liable for incidental or consequential damages We neither assume nor authorize any person to assume for it any other liability WARNING 1 DO NOT TEAR OFF OR REMOVE THE WARRANTY STICKER AS SHOWN OR THE WARRANTY IS VOID 2 WARRANTY VOID IF USE COMMERCIAL GRADE POWER SUPPLY IS USED AT HARSH ENVIRONMENTS Chinese SJ T 11364 2014 部件名称 有 毒 有 害 物 质 或 元 素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE ...

Reviews: