Press “Blink LED” to start the LED blinking immediately without SitePlayer restarting.
Telnet Test Mode
Telnet Test Mode is used to test SitePlayer’s Serial and Network connection. It is primarily there for tests per-
formed at the factory.
Active
- Test mode is activate (enabled)
Inactive
- Test mode is not active (not enabled)
Select which mode you want SitePlayer to be in and then press “Set Serial Test Mode.” The Test Mode setting
is not saved when you reflash SitePlayer.
To properly test SitePlayer using this mode, two SitePlayers are used. Their serial ports are connected to-
gether via a Null modem cable. Their Ethernet ports are either connected together via an Ethernet cross-
over cable or through a hub. One SitePlayer is set as server and the other SitePlayer is set as client. At least
one SitePlayer needs to be set to Active mode. The baud rates need to be the same on both SitePlayers and
they must have some kind of flow control enabled.
Both SitePlayers should be power up simultaneously, although they wait 15 seconds before they begin the
test. Each SitePlayer in Active mode initiates the test by sending the characters ‘A’ through ‘Z’ to the other
SitePlayer. Because the SitePlayers are wired in a loop, they send characters on the serial port and network
continuously.
Restart SitePlayer
Press the “Restart SitePlayer” button to force Siteplayer to restart itself. Any active network connections will
be lost when SitePlayer restarts.
Set to Factory Defaults
Press “Set to Factory Defaults” to cause SitePlayer to erase its persistent storage. SitePlayer will revert to a fac-
tory default configuration. The current Website will be erased, but the current Firmware will not be altered.
This operation will take about 1 minute. During this time, SitePlayer’s LED will be blinking indicating that the
persistent storage is being erased. Do not remove power while this is happening. After the persistent stor-
age is erased, SitePlayer will restart and revert to a minimal web page:
You should reload the WebSite ROM file so that you can reconfigure SitePlayer. See the
Update Web Page
section on how to reload the WebSite ROM file.
•
•