Power Supply Cords

The following power supply cords are provided in the package with the PSU:

Each power cord is enclosed in a plastic wrapper with it’s model number and product name 
on it. Locate the correct cord based on your region.

If you use a 110 V AC power supply cord, the maximum DC output power of the PSU is 700 
W. If you use a 220V AC power supply cord the maximum DC output power of the PSU is 
1200 W.

All power supply cords must meet the following requirements:

•     

The power supply cord must be agency-certified for country of use, and rated at 10A by 

in-country regulatory authority.

•     

The power supply cord must have an IEC 320 C13, 90-degree angle plug to connect to 

the IEC320 C14 connector on the power supply.

•     

The power supply cord must have an appropriately rated and approved wall plug 

applicable to the country of installation.

•     

For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm

2

) minimum; over 

6 feet, the minimum wire size is 16 AWG (1.0 mm

2

). 

WARNING!

Make sure that the source outlet is properly grounded before 
plugging the AC power cord into the 8800 Series 100-240VAC PSU.

Pre-Installation Requirements

You need the following tools and equipment to install or remove a 8800 Series 100-240VAC PSU:

•     

ESD-preventive wrist strap

•     

Power supply cord

•     

Thermal protective gloves (required for removal; PSU may be hot to touch)

Table 1.  Power supply cords

Model

Product Name

Region

10041

Power cord, 10A, NEMA 5-15P, IEC320-C13, Right Angle North America

10042

Power cord, 12A, JISC8303, IEC320-C13, Right Angle

Japan

10043

Power cord, 10A, CEE 7/7, IEC320-C13, Right Angle

Europe

10044

Power cord, 10A, BS1363, IEC320-C13, Right Angle

Great Britain

10046

Power cord, 10A, NAS3112, IEC320-C13, Right Angle

Australia

Summary of Contents for PSU XCM88PS1

Page 1: ...350 East Plumeria Drive San Jose CA 95134 USA February 2011 201 13472 02 1 0 8800 Series 100 240VAC PSU XCM88PS1 Hardware Installation Guide ...

Page 2: ...er Countries See Support information card Trademarks NETGEAR the NETGEAR logo ReadyNAS ProSafe Smart Wizard Auto Uplink X RAID2 and NeoTV are trademarks or registered trademarks of NETGEAR Inc Microsoft Windows Windows NT and Vista are registered trademarks of Microsoft Corporation Other brand and product names are registered trademarks or trademarks of their respective holders Statement of Condit...

Page 3: ...nts Overview 4 Safety Information 4 Power Supply Cords 6 Pre Installation Requirements 6 Installing an 8800 Series 100 240VAC PSU 7 Removing an 8800 Series 100 240VAC PSU 9 Front Panel LEDs 10 Fuse 10 Specifications 10 ...

Page 4: ...odate up to six hot swappable 8800 Series 100 240VAC PSUs See the NETGEAR 8800 Series Chassis Switch User Manual for information on configuring your switch The front panel on each 8800 Series 100 240VAC PSU contains two cooling fans Airflow enters from the front vents on the PSU and exits to the rear vents of the switch Airflow through the 8800 Series 100 240VAC PSU AC is independent from the airf...

Page 5: ...en Webseite zum Download zur Verfügung www netgear com WARNING NETGEAR 8800 Series 100 240VAC PSUs do not have switches for turning the unit on and off Remove the wall plug from the electrical outlet to disconnect the power to an 8800 Series 100 240VAC PSU Ensure that this connection is easily accessible Do not connect the power supply into an electrical outlet when the power supply is outside the...

Page 6: ...n the power supply The power supply cord must have an appropriately rated and approved wall plug applicable to the country of installation For cords up to 6 feet 2 m long the wire size must be 18 AWG 75 mm2 minimum over 6 feet the minimum wire size is 16 AWG 1 0 mm2 WARNING Make sure that the source outlet is properly grounded before plugging the AC power cord into the 8800 Series 100 240VAC PSU P...

Page 7: ...ive wrist strap to your bare wrist and connect the metal end to the ground receptacle at the top left corner of the switch front panel 2 Verify that the PSU is right side up and the locking handle is open as shown in the following figure Figure 1 8800 Series 100 240VAC PSU with locking handle open 3 Carefully slide the 8800 Series 100 240VAC PSU all the way into the power supply bay see the follow...

Page 8: ...sary remove the power cord retaining bracket as described in the hardware installation guide for your switch b Connect the new AC power cord to the AC input on the front of the switch to the wall outlet on the other end after the cord is connected re install the power cord retainer c Attach the power cord retaining bracket as described in the hardware installation guide for your switch Note Leave ...

Page 9: ...are installation guide for your switch b Completely disconnect and remove the old power cord c Connect the new AC power cord to the AC input on the front of the switch and then connect the opposite end of the AC power cord to the wall outlet d After the cord is connected re install the power cord retainer Note For information about power cord requirements see Power Supply Cords on page 6 3 Lift th...

Page 10: ... 8800 Series 100 240VAC PSUs In the event of failure immediately return the defective PSU for a complete replacement Specifications The 8800 Series 100 240VAC PSU functions from 90 V to 264 V and 47 Hz to 63 Hz AC Input Each PSU provides 700 W to the system if the AC input is in the 110 V low line output power range and 1200 W to the system if the AC input is in the 220 V high line output power ra...

Page 11: ...ower Supply Specifications Characteristic Specification Nominal Input 100 240 V 60 50 Hz 10 A max AC Voltage Input Range 90 264 V Maximum Input Amperages 7 A 200 V high line 10 A 90 V low line AC Line Frequency 47 to 63 Hz AC Power Supply Input Socket IEC 320 C14 Minimum Wire Size 16 AWG 1 0mm2 copper stranded pre approved cord set for county of use Output DC Output 48 V 24 A 12 V 4 A high line 48...

Reviews: