background image

10

   

|   

Chapter   100-240VAC PSU XCM88PS1 Installation Note  

8800 Series 100-240VAC PSU XCM88PS1 Installation Guide

Front Panel LEDs

The front panel of the 8800 Series 100-240VAC PSU provides status LEDs. The following 
table describes the operation of these LEDs.

Fuse

The 8800 Series 100-240VAC PSU line and neutral legs are both fused. Power to the switch 
may still be live if the neutral fuse is open. This is not a field operator replaceable fuse. In the 
event of failure, immediately return the 8800 Series 100-240VAC PSU for a complete 
replacement.

WARNING!

Field operators must not attempt to configure or replace fuses 
within 8800 Series 100-240VAC PSUs! In the event of failure, 
immediately return the defective PSU for a complete replacement.

Specifications

The 8800 Series 100-240VAC PSU functions from 90 V to 264 V and 47 Hz to 63 Hz AC 
Input. Each PSU provides 700 W to the system if the AC input is in the 110 V low-line output 
power range and 1200 W to the system if the AC input is in the 220 V high-line output power 
range.

Table 2.  8800 Series 100-240VAC PSU Front Panel LEDs

PSU Condition

Power 
Green

Predictive Fail
Amber

Fail
Amber

Power supply AC outputs working normally

On

Off

Off

AC input power present/standby output on

Blinking

Off

Off

Current limit on 48 VDC output

On

Off

Blinking

Predictive failure

On 

Blinking

Off

No input power to this PSU only

Off

Off

On

No input power to any PSU

Off

Off

Off

Power supply failure

Off

Off

On

Summary of Contents for PSU XCM88PS1

Page 1: ...350 East Plumeria Drive San Jose CA 95134 USA February 2011 201 13472 02 1 0 8800 Series 100 240VAC PSU XCM88PS1 Hardware Installation Guide ...

Page 2: ...er Countries See Support information card Trademarks NETGEAR the NETGEAR logo ReadyNAS ProSafe Smart Wizard Auto Uplink X RAID2 and NeoTV are trademarks or registered trademarks of NETGEAR Inc Microsoft Windows Windows NT and Vista are registered trademarks of Microsoft Corporation Other brand and product names are registered trademarks or trademarks of their respective holders Statement of Condit...

Page 3: ...nts Overview 4 Safety Information 4 Power Supply Cords 6 Pre Installation Requirements 6 Installing an 8800 Series 100 240VAC PSU 7 Removing an 8800 Series 100 240VAC PSU 9 Front Panel LEDs 10 Fuse 10 Specifications 10 ...

Page 4: ...odate up to six hot swappable 8800 Series 100 240VAC PSUs See the NETGEAR 8800 Series Chassis Switch User Manual for information on configuring your switch The front panel on each 8800 Series 100 240VAC PSU contains two cooling fans Airflow enters from the front vents on the PSU and exits to the rear vents of the switch Airflow through the 8800 Series 100 240VAC PSU AC is independent from the airf...

Page 5: ...en Webseite zum Download zur Verfügung www netgear com WARNING NETGEAR 8800 Series 100 240VAC PSUs do not have switches for turning the unit on and off Remove the wall plug from the electrical outlet to disconnect the power to an 8800 Series 100 240VAC PSU Ensure that this connection is easily accessible Do not connect the power supply into an electrical outlet when the power supply is outside the...

Page 6: ...n the power supply The power supply cord must have an appropriately rated and approved wall plug applicable to the country of installation For cords up to 6 feet 2 m long the wire size must be 18 AWG 75 mm2 minimum over 6 feet the minimum wire size is 16 AWG 1 0 mm2 WARNING Make sure that the source outlet is properly grounded before plugging the AC power cord into the 8800 Series 100 240VAC PSU P...

Page 7: ...ive wrist strap to your bare wrist and connect the metal end to the ground receptacle at the top left corner of the switch front panel 2 Verify that the PSU is right side up and the locking handle is open as shown in the following figure Figure 1 8800 Series 100 240VAC PSU with locking handle open 3 Carefully slide the 8800 Series 100 240VAC PSU all the way into the power supply bay see the follow...

Page 8: ...sary remove the power cord retaining bracket as described in the hardware installation guide for your switch b Connect the new AC power cord to the AC input on the front of the switch to the wall outlet on the other end after the cord is connected re install the power cord retainer c Attach the power cord retaining bracket as described in the hardware installation guide for your switch Note Leave ...

Page 9: ...are installation guide for your switch b Completely disconnect and remove the old power cord c Connect the new AC power cord to the AC input on the front of the switch and then connect the opposite end of the AC power cord to the wall outlet d After the cord is connected re install the power cord retainer Note For information about power cord requirements see Power Supply Cords on page 6 3 Lift th...

Page 10: ... 8800 Series 100 240VAC PSUs In the event of failure immediately return the defective PSU for a complete replacement Specifications The 8800 Series 100 240VAC PSU functions from 90 V to 264 V and 47 Hz to 63 Hz AC Input Each PSU provides 700 W to the system if the AC input is in the 110 V low line output power range and 1200 W to the system if the AC input is in the 220 V high line output power ra...

Page 11: ...ower Supply Specifications Characteristic Specification Nominal Input 100 240 V 60 50 Hz 10 A max AC Voltage Input Range 90 264 V Maximum Input Amperages 7 A 200 V high line 10 A 90 V low line AC Line Frequency 47 to 63 Hz AC Power Supply Input Socket IEC 320 C14 Minimum Wire Size 16 AWG 1 0mm2 copper stranded pre approved cord set for county of use Output DC Output 48 V 24 A 12 V 4 A high line 48...

Reviews: