HyPer 9HV IS User Manual Version 06
NetGain Motors, Inc.
Page 27 of 28
64
Main Contactor Close
Command Timeout
Pre-charge timer has expired before the master sends the power
ready request.
Blocking
65
Blocking Request From
Master
Fault Request is received from Master.
Blocking
66
Not Assigned
-
Not
Assigned
67
Net Startup Timeout
The node hasn't been able to synchronize itself to the network.
Blocking
68
Net External Failure
At least one Node has become not operational.
Stopping
69
Net Mains Manager
Wrong Sequence
The Main Contactor Manager has executed a wrong powering
procedure.
Blocking
70
Net Mains Manager
Precharge Too Slow
DC Bus Voltage will not increase after discharging phase.
Blocking
71
Net Mains Manager
Closing Too Slow
The main contactor doesn't close.
Blocking
72
Net Mains Manager
Powering Alarm
At least one fault has occurred on Main Contactor Manager
Controller.
Blocking
73
CO Synchro Failed
At least one node of the network could be wrong configured or
switched off.
Blocking
74
CO Synchro Lost
At least one node of the network could be wrong configured or
switched off during operation.
Stopping
75
Stopped For System
Fault
Node is stopped because another node has a stopping/blocking
fault condition.
Stopping
76
Blocked for System Fault
Node is blocked because another node has a stopping/blocking
fault condition.
Blocking
77
BMS Wall Charge
The TAU Node sets a blocking fault.
Blocking
78
BMS Stop
The TAU Node sets a stopping fault
Stopping
79
BMS Fault
The TAU Node sets a blocking fault.
Blocking
80
BMS Limiting
The TAU Node limits its current to the required value from BMS. Limiting
81
Steering Sensor Fault
A fault condition of steering sensor is detected.
Limiting
82
CAN Protocol Run Time
Error
Wrong Request for Driver Outputs
Limiting
83
Programming Required
Controller Firmware Programming
Blocking
84
DigInputs Overvoltage
Digital Input Supply has reached dangerous value
Blocking
85
Inverter Model Not
Supported
Inverter model is not supported by the firmware.
Blocking