background image

34

35

Test results

Powertimer measures the sprint time and calculates following 
results:

• 

Vertical Velocity

 in meters per second

• 

Work

 in joules

• 

Sprint Power

 in watts

• Relative Power 

in watts

8.10 Running-Based Anaerobic Sprint Test (RAST)

Test description

In 

Running-Based Anaerobic Sprint Test 

(RAST) the subject 

sprints six 35-meter sprints with a 10-second recovery be-
tween the sprints. The test measures short-term anaerobic 
sprint power.

Test parameters

Since the number of sprints and sprint distance is given in the 
test description, RAST does not have any parameters that can 
be changed.

Test sequence

The subject starts the test by doing the first sprint and the 

Per-

forming Test

 notification will be shown. After the subject has 

done the first sprint and waited the 10-second recovery time, 
the 

Measurement Unit

 will beep and the subject needs to 

sprint back. After six sprints the test is complete.

Test results

The sprint times are measured and following results calculat-
ed:

• Power

 of each sprint in watts

• Relative Power
• Average Power

 of the sprints

• Velocity 

in meters per second

• Fatigue Index 

is the relation between the best and worst 

jump powers

8.11 Reactivity / Stiffness Test (Reactivity-Stiffness)

Test description

The 

Reactivity / Stiffness Test 

is used to measure the explosive 

strength and utilization of the elastic energy in the plantar flex-
ors. The subject begins the jumps outside the jump mat and 
the first jump lands on the jump mat. She then continues jump-
ing on the mat until the pre-determined number of contacts 
jumps is achieved.

Test parameters

The test has only one parameter: The number of jumps to be 
performed in one test action.

Test sequence

The subject steps on the jump mat and starts jumping. Subject 
then continues jumping until the predefined amount of jumps 
has been performed. Note that 

Powertimer

 does not prevent 

the subject from stopping, having a break and then continuing 
the jumping.

Test results

Powertimer

 measures the jump and contact times and calcu-

lates following results:

• 

Jump Height 

in centimeters or inches depending on the re-

gional settings

• 

Jump Power 

for each jump in watts

• 

Relative Power

 for each jump in watts

� � �� �

� �� ��

�������� ���� �� � �

� � � � � �� ���� �

����� �� � �

��

Figure 53

 Margarias´s Stair Run Test

Summary of Contents for Powertimer SW-300

Page 1: ...POWERTIMER SW 300 FOR PALM OS 2 USER S MANUAL Powertimer SW 300 ENG...

Page 2: ...manner not expressly authorized by this License You ac knowledge and agree that ownership of the Software and allsubsequent copies thereof regardless of the form or media are held by Newtest The Softw...

Page 3: ...23 6 2 Subjects 24 Adding a new subject 24 Changing birth date 24 Editing height and weight 25 Changing sport 25 Measuring fat 25 Assigning subject to groups 26 Subject manager actions 26 7 Other fun...

Page 4: ...3 and check chapter 2 if you are having prob lems with the user interface Chapter 3 gives a tutorial on how to perform a Drop Jump test After this chapter you should be familiar with the basics of te...

Page 5: ...idual that performs tests A sub ject may belong to multiple test groups for example if the sub ject plays ice hockey and football in two different teams Syn chronization removes all subjects from Powe...

Page 6: ...sult contains the following properties Result ID is a number that identifies the result for example ID 27 Test Action this result belongs to Type of result for example Contact Time Value of the result...

Page 7: ...u cannot create a new group by changing the name of an ex isting group since the existing group gets overwritten when synchronizing The relations between existing subjects and groups are nev er update...

Page 8: ...Palm Just tap on the Powertimer icon to start Powertimer SW 300 When program starts the screen goes blank for a while At the mo ment there is no solution that can prevent this The Main View shown in F...

Page 9: ...ains Figure 5 shows an example of an open selector Tap ping on one of the list elements selects the element and closes the selector Powertimer may contain more data that is possible to show in a selec...

Page 10: ...beti cal order Text boxes Text boxes come in two variations Value boxes and normal text boxes Value boxes contain up and down arrows beside them and only allow numerical data Normal text boxes allow a...

Page 11: ...nd a Sub jects using Powertimer SW 300 3 1 Test sessions When the Powertimer SW 300 is started the Main View is shown To start testing you must first create a Test Session Sessions are used to group s...

Page 12: ...ll re turn to the Edit Session view If the Name and Comments are satisfactory pressing Save Exit again saves the new session and returns to the Session Manager The new session is now visible in the li...

Page 13: ...and Re sult Specific Parameters Global Parameters are test specific parameters that affect all Test Actions that are started in the future Test Specific Parameters only affect the current test in pro...

Page 14: ...the Start Test action and tap the Do Action button Before you do that make sure that the Powertimer Measurement Unit is turned on and the se rial cable between Powertimer SW 300 and the Measurement Un...

Page 15: ...logical to say that one Drop Height is better than another Tapping on a result in the Best column will show the ID of the best result as shown in Figure 26 so that the best result can be fully viewed...

Page 16: ...Result ac Most tests have more calculated results that can be fitted into one page For that purpose the Page Selector at the left side below the Results label is provided The up and down arrows are u...

Page 17: ...he subject cannot perform more jumps If the results are not satisfactory the Edit Results button returns to the normal view where the action selector will be visible The action selector can then be us...

Page 18: ...osing Show Test Results action The viewer has five selectors Four of them are used to filter Test Actions and one shows the Test Actions that comply with the current filtering rules If a Test Group is...

Page 19: ...est fil ters to locate the required test actions After you have done the filtering the Results selector shows all Test Actions that comply with the filtering rules If no filtering rules are speci fied...

Page 20: ...s training example do the following 1 Set up two photocells 10 meters apart 2 Start Powertimer 3 Start ST test using the session created in the Drop Jump ex ample 4 Set the ST parameters to 10 meter d...

Page 21: ...ow the results made by the subject and the Differ ence field will show the difference to the original result Neg ative values mean that the subject was slower than the Target Result and positive value...

Page 22: ...e created using the Powertimer SW 300 Adding a new group To add a new group tap on the Groups button in the Main View This enters the Group Manager shown in Figure 36 From the Group Manager choose the...

Page 23: ...t is selected from the groups list Chapter 4 explains the usage of the Result Viewer The Show Subjects and Show Sessions actions enter the Sub ject Manager or Session Manager If these managers are en...

Page 24: ...d dle initials to separate them from each other It is possible to have multiple subjects with the same last name and initials but it will make things more complicated since you cannot know which of th...

Page 25: ...gure 42 Anthropometrical Data Editor Changing sport Selecting the Edit Sport action and tapping the Do Action but ton enters the Sport Chooser view that allows you to select the sport for the subject...

Page 26: ...ject Manager Subject manager actions To remove an existing subject select the subject from the list choose the Remove Subject action from the action selector and tap the Do Action button A confirmatio...

Page 27: ...he lights of the Measurement Unit can be set by clicking the menu item Worklight on the menu of the Main View 7 2 Connection tester The Connection Tester view is available from the menu of the Main Vi...

Page 28: ...change the measurement units There are two possible length units and two possible weight units Changes to these settings OTHER FUNCTIONS OF POWERTIMER SW 300 7 Figure 46 Measurement Unit Tester are sa...

Page 29: ...s MRP Parameters of measurement results TPs Global test parameters There should be 19 entries in the Tests database and 37 en tries in the Test Parameters database Other databases may contain a variab...

Page 30: ...Powertimer knows that the sub ject was not actually jumping Powertimer also starts to meas ure a jump when the subject leaves the jump mat for example to climb on the platform in Drop Jump Also in th...

Page 31: ...erforming the test and the number of sprints the subject managed to per form The total distance run is calculated from the number of sprints The aerobic capacity VO2max is calculated from these measur...

Page 32: ...g jump notifi cation This is normal behavior since Powertimer assumes that the subject is going to land on the jump mat To create more results the subject just sprints over the jump mat again until th...

Page 33: ...ength and stretch tolerance performance In DJ the subject starts his jump performance on a platform The subject jumps from the platform to the jump mat and then jumps as high as possible Test paramete...

Page 34: ...rints from the starting photocell to the finishing photocell Powertimer measures the total time and the split times if they exist Test results ST contains three pages of results however if there are n...

Page 35: ...in watts Relative Power Average Power of the sprints Velocity in meters per second Fatigue Index is the relation between the best and worst jump powers 8 11 Reactivity Stiffness Test Reactivity Stiffn...

Page 36: ...er Powers for each of the 15 second period of jumps Power Decline is the difference between average of the three first jumps and the average of the three last jumps Fatigue Index is the relation betwe...

Page 37: ...use the following meas urement points ACSM uses all points except Bicep D W uses the Bicep Suprailiac Subscapular and Triceps points If you have already measured the fat of a subject using some other...

Page 38: ...The subject starts each jump with a 90 degree knee angle and performs the number of jumps specified in the test parameters If the subject leaves the jump mat before the test is complete the Powertimer...

Page 39: ...asses Test parameters Throwing Gate Test has seven parameters The Distance from the photocell to the jump mat or second photocell the number of throws to be performed with each ball mass and the five...

Page 40: ...wertimer measures the flight time and calculates the Velocity from that A graph is also available by selecting the Mass Vel Curve action The graph shows the relation between the ball mass and the velo...

Reviews: