background image

Delta 1600 - Quick-Reference Manual | 

3

Notices

Unpacking and Inspection of the unit

Before unpacking the Delta 1600, inspect the shipping box for any 
visual damage. If damage is found, do not unpack the unit and 
immediately notify the shipping carrier.  If no damage is found to the 
shipping box, open the box and perform a visual inspection of the 
Delta 1600. If any damage to the unit is observed please contact 
Netech Customer Service.  

The Service Return Form may be obtained at our website http://

www.

netechcorp.us/RMARequests

 or contact our 

Netech Customer 

Service Department 

[email protected]

Contact Information

Netech Corporation, 110 Toledo St. Farmingdale, NY 11735

Phone: 

631-531-0100, 1-800-547-6557

Calibration 

The Delta 1600 is factory calibrated, thoroughly tested, and meets 
Netech’s ISO 9001-2015 quality standards. 
Any attempt to remove or tamper with the calibration seal will void 
the warranty.

Warnings

Caution  Important Safety Information

Hazardous Voltage

Conforms to European Union Directive

SYMBOL  

        DESCRIPTION

Summary of Contents for Delta 1600

Page 1: ...External Defibrillator Tester Intended Use Delta 1600 AED Tester is a precision instrument that simulates various cardiac waveforms and measures discharged energy It assures AEDs detect the waveforms...

Page 2: ...tended User 4 Environment 4 Introduction 5 Delta 1600 Features 5 Specifications 6 Energy Measurement 6 General Specifications 7 Part Numbers and Ordering Information 8 Preparation for Use 9 Initial Se...

Page 3: ...ustomer Service The Service Return Form may be obtained at our website http www netechcorp us RMARequests or contact our Netech Customer Service Department Customerservice netechCorp us Contact Inform...

Page 4: ...ation where it might come in contact with a patient The Delta 1600 is intended to be used within the published specifications Any unauthorized alteration or modifications will result in a hazardous co...

Page 5: ...The Delta 1600 has a built in load resistance of 50 ohms to simulate the human body impedance To establish electrical connection between the AED and the Delta 1600 manufacturer specific interface cabl...

Page 6: ...J Accuracy 1 of reading 1 Load Resistance 50 ohms 1 non inductive 1 H Sampling Time 20 uS Measurement Time Window 60 ms Pulse Width 60 ms Patient Simulator Waveform Simulation ECG NSR ECG Rate 60 70...

Page 7: ...r Tachycardia VTAC Atrial Fibrillation AFIB General Specifications Temperature Range Operating 15 C to 35 C Storage 0 C to 50 C Display Type LCD with LED backlit Graphics display Power 7 4 Volt Li Ion...

Page 8: ...1 ZOLL ZOLL 630 651 SURVIVAL Cardiac Science Survivalink Burdick Cardiovive 630 651 PHYSIO Physio Control Life Pak Medtronic 630 612 Philips HeartStart FRx 630 615 Philips and Laerdal HeartStart FR3 6...

Page 9: ...Delta 1600 AED Tester Li Ion Rechargeable Battery Charger 110 220 V input User manual USB Jump Drive Before getting started it is important to get familiar with the control and operation of the unit...

Page 10: ...lowing are the description of the Key Functions F1 F2 F3 F4 and These are interactive keys associated with respective function selections ESC Reverts to the previous menu AUTO Pressing AUTO key change...

Page 11: ...y Charger Li Ion Battery Charger provided with the unit is specifically designed for the Delta 1600 When the battery is fully charged the red LED on the CHARGER changes to green Battery Delta 1600 inc...

Page 12: ...Press F2 ECG for the ECG Rate and Amplitude Menu Initial Setup Introduction The Delta 1600 is simple to operate and requires minimum setup However the user must read the manual thoroughly for safe and...

Page 13: ...ng F1 F2 F3 or F4 The selected Arrhythmia waveform will be displayed flashing as illustrated below Turn the AED power ON and follow the manufacturer s operating instructions and the audio response Sho...

Page 14: ...AED and wait until the energy is discharged Once discharged the energy will be displayed as illustrated below If the response is no shock advised select a different arrhythmia waveform from the arrhy...

Page 15: ...multiple discharges and helps preserve the battery life of the AED Select AUTO key and wait for the AED s response The default arrhythmia waveform is set to VFBC If shock advised discharge the AED The...

Page 16: ...function can be selected from the following ECG selection menu Rate Selection The default ECG rate is set 90 BPM ECG rate can be changed in 10 BPM increments from 60 BPM up to 200 BPM and 20 BPM incr...

Page 17: ...ival at our facility These warranties are made upon the expressed condition that 1 The purchaser promptly notifies Netech in writing of any non conformity with the above warranty including a detailed...

Page 18: ...ling charges will be billed to the purchaser THIS WARRANTY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND OR...

Page 19: ...Delta 1600 Quick Reference Manual 19 Appendix A Netech warrants this instrument to the original purchaser as Current Revision R1 06 12 17...