4. Extend the rear section of the rail to the rear post of the rack.
5. Align the hooks on the rear of the rail with the appropriate holes on the rear post ensuring that the front and
the back of the rail are on the same level.
6. Mount the rear of the rail onto the rack, and secure the rail with screws.
7. Perform all the above steps for the other side of the rack.
H610S
Here is an illustration for installing rails for an H610S storage node:
There are left and right rails on the H610S. Position the screw hole towards the bottom so that
the H610S thumbscrew can secure the chassis to the rail.
Install and cable the nodes
You install the H410S storage node in a 2U, four-node chassis. For H610S, install the chassis/node directly
onto the rails in the rack.
Remove all the packing material and wrapping from the unit. This prevents the nodes from
overheating and shutting down.
•
5