Handle to pull the fan module out
6. Slide the replacement fan module all the way into the shelf, moving the fan module handle to the side until
it latches with the orange tab.
7. Check the amber Attention LED on the new fan module.
After you replace the fan module, the Attention LED stays on (solid amber) while the
firmware checks that the fan module was installed correctly. The LED goes off after this
process is complete.
8. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit.
Contact technical support at
, 888-463-8277 (North America), 00-800-44-638277 (Europe),
or +800-800-80-800 (Asia/Pacific) if you need the RMA number.
Hot-remove a shelf - shelves with IOM12 modules
You can hot-remove a disk shelf with IOM12 modules (nondisruptively remove a disk
shelf from a system that is powered on and I/O is in progress) when you need to move or
replace a disk shelf. You can hot-remove one or more disk shelves from anywhere within
a stack of disk shelves or remove a stack of disk shelves.
Before you begin
34
Summary of Contents for DS212C
Page 18: ...16 ...
Page 22: ...Orange ring on horizontal bracket Cable chain 20 ...
Page 32: ...Guide rail 30 ...
Page 57: ...Attention LED light on 55 ...