Chapter 3: Replacing Disk Shelf Devices
53
3
If the disk shelf connects to a...
Then...
System with Data ONTAP 7.x or earlier
installed
From the system console, enter the following
command to disable the loop in which the failed
module is a connection:
storage disable adapter adaptername
The Data ONTAP System Administrator’s Guide
(7.0.1 or later) provides more information about
these commands.
System with Data ONTAP 10.x installed
1. Log into the system and enter the following
command at the console to go to the shell
command mode:
ngsh
2. Enter the following command at the console to
go to the command line interface:
dbladecli
3. Enter the following command to disable the
loop in which the failed module is a
connection:
storage disable adapter adaptername
4
If you are hot-swapping like modules, disconnect the module that you are removing from the
Fibre Channel cabling.
5
Using the thumb and index finger of both hands, press the levers on the CAM mechanism on the
module to release it and pull it out of the disk shelf.
6
Slide the module into the slot at the rear of the disk shelf and push the levers of the CAM into
place.
Attention
Do not use excessive force when sliding the module into the disk shelf; you might damage the
connector.
7
Use the appropriate cable to reconnect both modules of the disk shelf to the other disk shelves or
to your system. See “
Disk shelf cabling requirements
” on page 32 for additional requirements.
Step
Action
Summary of Contents for DiskShelf14mk2 FC
Page 12: ...6 Before you begin your installation For DS14mk2 FC ...
Page 23: ...Chapter 2 Monitoring the Disk Shelf 17 For DS14mk2 FC ...
Page 36: ...30 Monitoring the Fibre Channel disk For DS14mk4 FC ...
Page 72: ...66 Hot adding a disk shelf to an existing adapter in your system ...
Page 90: ...84 Index ...