If your system is running
ONTAP…
Then…
Resulted in some test failures
Determine the cause of the problem.
a. Exit Maintenance mode:
halt
b. Perform a clean shutdown, and then disconnect the power
supplies.
c. Verify that you have observed all of the considerations identified
for running system-level diagnostics, that cables are securely
connected, and that hardware components are properly installed
in the storage system.
d. Reconnect the power supplies, and then power on the storage
system.
e. Rerun the system-level diagnostics test.
Step 3: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Controller module
Overview of controller module replacement - AFF A200
You must review the prerequisites for the replacement procedure and select the correct
one for your version of the ONTAP operating system.
What you’ll need
• All drive shelves must be working properly.
• If your system is in an HA pair, the healthy controller must be able to take over the controller that is being
replaced (referred to in this procedure as the “impaired node”).
About this task
• You must replace the failed component with a replacement FRU component you received from your
provider.
• You must replace a controller module with a controller module of the same model type. You cannot
upgrade your system by just replacing the controller module.
• You cannot change any drives or drive shelves as part of this procedure.
• In this procedure, the boot device is moved from the impaired controller to the
replacement
node so that
the
replacement
node will boot up in the same version of ONTAP as the old controller module.
• It is important that you apply the commands in these steps on the correct systems:
◦
The
impaired
node is the controller that is being replaced.
◦
The
replacement
node is the new controller that is replacing the impaired controller.
◦
The
healthy
node is the surviving controller.