24
FERTIKIT 3G
INSTALLATION MANUAL
DESCRIPTION
Dosing channel
Scope of delivery
Direction of flow
14
15
13
16
17
18
19
20
21
16
5
8
10
1
2
3
4
6
7
9
11
12
26
27
22
MX mode
Operating principle:
The pressure differential required to
generate fertilizer suction via the Venturis is produced by
a booster pump integrated in the FertiKit
TM
.
This mode of operation, where the lower manifold
is under low pressure (around 0 bars/PSI), permits the use of
high-efficiency Venturis with high suction capacity and low motive
flow consumption. PRV
27
and PSV
26
as standard.
Flow rate:
20 - 700 m³/h (85 - 3000 GPM)
Suitable for main line pressure:
2.5 - 8.5 bars (36 - 123 PSI)
Dosing channels:
Accommodates a wide variety of dosing channels for
fertilizer and concentrated/diluted acid:
•
Up to 5 x 50 - 1000 l/h (13 - 265 GPH)
•
Includes compensation channel
•
Optional - Concentrated acid channel, 50 l/h (13 GPH)
.
Total fertilizer/acid suction capacity:
•
Up to 5000 l/h (1320 GPH).
Controller:
NMC-Pro, NMC-XL, NMC-Junior,(Other controllers or manual system without controller - optional).
EC/pH:
Single, monitoring and control.
Schematic diagram