![Net2Edge LIB-306 Install Manual Download Page 12](http://html1.mh-extra.com/html/net2edge/lib-306/lib-306_install-manual_1669718012.webp)
Net2Edge
LIB-306 Install Guide
Install Guide Rev. D
www.net2edge.com
Page 12 of 25
Alarm Inputs
Wire state
Trigger
setting
Alarm state & LED
behavior
Energized
Close
Asserted & Active
De-energized
Close
De-asserted & Not active
Energized
Open
De-asserted & Not active
De-energized
Open
Asserted & Active
Connecting Power
You can connect LIB-306 power can be powered either via a DC or AC Source
– or both.
Note that when power is initially applied (or when power is recycled) the LIB-306 front panel LEDs all light
for approximately 10 seconds. Some LEDs will remain lit, depending on the LIB-306 operating status and
port connections.
Notes
:
The range of suitable wire for the DC power terminal screws is 12 to 26 AWG.
The DC power source must be safety certified.
Connecting Power Wires to the DC power connectors
1.
Strip the wires to the proper length.
2.
Insert the positive and negative power wires into the two outer screws on the DC power supply input
(the DC power supply is polarity insensitive, so there is no designated V+ or V– screw connector).
Make sure the wires are secure.
3.
Insert the power wires from the LIB-306 into V+ and V- contacts in the power source—make sure the
wires are secure.
4.
Turn the power source ON and observe that the green front panel PWR (power) LED is lit, indicating
that power is applied to the LIB-306.