Ness R8
- Installation and Programming Manual
28
PROGRAMMING
Instant Zones operate only in the Armed state. Once armed at the
expiry of exit time, Instant Zones will activate assigned outputs
immediately when triggered.
PROGRAMMING SEQUENCE
1. Press:
P40E
2. Press:
[1-8] E
• This enables the zone for this option. To deselect a zone from this
option, program it to be Entry Delay or Handover.
• Zone light on indicates the option is enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
3–8 = ON, Zones 3–8 are
instant.
NOTES:
• When a zone is selected as
Instant, it is automatically
deselected from Entry Delay
or Handover.
P40E
INSTANT ZONES
Entry Delay zones operate only in the Armed state. When Armed,
at the expiry of exit time these zones will activate the Entry Delay
Timer (P26E) when they are triggered. If the panel is not disarmed
before the expiry of the Entry Delay Timer, the alarm outputs will be
activated.
PROGRAMMING SEQUENCE
1. Press:
P42E
2. Press:
[1-8] E
to enable each zone for this option.
• To deselect a zone from this option, program it to be Instant or
Handover.
• Zone light/s on indicates which option is enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
1 = ON, Zone 1 is Delayed.
NOTES:
• When a zone is selected as
Entry Delay, it is
automatically deselected
from Instant or Handover.
P41E
ENTRY DELAY ZONES
Handover zones are delayed only if entry is made through an Entry
Delay zone first. If a Handover zone is triggered first, the zone
behaves as an instant zone. Normally, the “point of entry” zone
should be Delay zone, with any other zones in the entry path
programmed as Handover zones.
PROGRAMMING SEQUENCE
1. Press:
P42E
2. Press:
[1-8] E
to enable each zone for this option.
• To deselect a zone from this option, program it to be Delayed or
Instant.
• Zone light/s on indicates which option/s are enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
2 = ON, Zone 2 is Handover.
NOTES:
• When a zone is selected as
Handover, it is automatically
deselected from Entry Delay
or Instant.
P42E
HANDOVER ZONES