Ness ECO8x AlARm CONtROl pANEl

InstallatIon & programmIng manUal

ECo8x

Summary of Contents for ECO8x

Page 1: ...Revision 1 5 A 15 00 Ness ECO8x alarm control panel Installation programming MANUAL ECO8x ...

Page 2: ...069 984 372 Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au NSW Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au VIC Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au QLD Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au WA Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au SA Ph 08 8152 0000 Fax 08 8152 0100 adelaide ness com au ...

Page 3: ...me mode output mapping 26 Day mode output mapping 26 Miscellaneous Options 27 28 Aux1 Output options 29 Aux2 Output options 30 Misc options 31 33 Telephone Numbers 34 Account Numbers 35 Alarm reporting options 36 37 Test Call options 38 Dialler format options 39 44 Reset Factory Defaults 45 Special Installer Functions Send test report 46 Siren test Panel reset Display software version Radio Option...

Page 4: ...of static 3 Handle circuit boards by the edges Avoid touching any components on the board as the integrated circuits in particular are not guaranteed by their manufacturers to be safe from ESD 4 To minimise the build up of static avoid walking around as much as possible while working on the installation 5 Touch an earthed object to discharge any static before working on the installation INSTALLATI...

Page 5: ...enter Installer Program Mode inputs 12 Volt output A regulated 13 8 VDC output is available to power detectors and other equipment This output is protected by an Automatic Reset fuse A maximum load of 500mA may be connected Siren The on board siren driver will drive a maximum of 3 x 8 ohm horn speakers Ness Part No NOI110 The output will reset at the end of siren time P29E or whenever the panel is...

Page 6: ...nd can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines Use Ness ADSL Filters 100 006 or 100 009 Ness ECO8x Control Panel Installation Manual ...

Page 7: ...ONTROL PANEL NESS ECO8x NESS ECO8x CONTROL PANEL NESS ECO8x CONTROL PANEL 0V ALARM TAMPER N C N C 12V N C N C NESS QUANTUM DETECTOR all models REED SWITCH N C contacts PANIC BUTTON N O contacts Zone 1 8 Zone 1 8 Zone 1 8 Zone 1 8 0V C 12V 0V C C 12V 0V C C 12V 2K2 2K2 NESS QUANTUM DETECTORS 4 WIRE CONNECTION 0V ALARM TAMPER N C N C 12V N C N C NESS QUANTUM DETECTOR all models Any zone programmed a...

Page 8: ...e tamper alarm Device number is indicated by zone lights Keypad Display Indicators in Operating Mode Keypad light OFF ON Flashing ZONe Lights 1 8 Zone is sealed Zone is unsealed Zone is in alarm ARMED Red Illuminated button Panel is disarmed Panel is armed or Area 1 is armed if using Areas Home Yellow Illuminated button Home Mode is disarmed Panel is armed in Home Mode Day Mode enabled see page 18...

Page 9: ...ll disarm the panel and send a Duress report by dialler to the central station Report Keypad Duress must be enabled P75E1E Exclude Zones Exclude E can only be used when the panel is disarmed Exclude CODE E can be used anytime Press If the Exclude Shortcut is enabled P62E 2E then Zone No Zone No Enter the zone number s to be excluded then press to exit Exclude mode The Exclude light flashes constan...

Page 10: ...d one digit at a time 9 P E To exit program mode Program light will turn off Quick Start 2 Audible Monitoring Quick Start 2 shows you how to change User Code 1 the Master Code enable Audible Monitoring and program a telephone number This will enable the dialler to report alarms to any telephone including mobile phones Quick Start 3 Central Station Monitoring Quick Start 3 shows you how to change U...

Page 11: ...r to program All User Codes Entry Exit Times Follow Me Telephone number Note The panel will automatically exit User Program Mode to Operating Mode if no keypad buttons are pressed for 4 minutes How to enter Program Mode from Power Up 1 Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in Operating Mode or Using the keypad The panel must be disarmed 1 Press Master Code Thi...

Page 12: ... code the new code will overwrite the old code Deleting Keypad Codes To delete a User Code without programming a new code press the MEMORY key in place of the code Example To delete User Code 2 press P12E MEMORY E A keypad code only needs to be deleted if you re not replacing it with a new code Arm Only Codes Arm Only is an extra option for user codes See next page for further information User Cod...

Page 13: ...emove user codes to Area 1 By default all user codes are assigned to Area 1 2E Area 2 Codes Assign remove user codes to Area 2 User codes can be assigned to Area 1 Area 2 both areas or no areas An Area will not arm unless it has one or more zones assigned to it P45E P46E If a code is not assigned to any Area s the code can be used for special functions such as to trigger outputs 3E Arm Only User C...

Page 14: ...The Exit Delay Time setting is from 1 to 99 seconds in 1 second increments Programming sequence P28E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Exit Delay to be 85 seconds P28E 85E P28E Program Mode level User Installer Remote by PC Factory Default 60 seconds Notes Programmable from 1 99 seconds RELATED OPTIONS P62E ...

Page 15: ...orizontally and the arrow must point up for any required setting Vibration Sensitivity Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Zone sensitivity is adjusted by toggling zones ON in options P30E to P36E P30E is Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 36E are the options f...

Page 16: ...RY E to turn all selections ON instant Zones Instant Zones operate only in the Armed state When Armed at the expiry of exit time Instant Zones will activate assigned outputs immediately when triggered P40E Zone No E turns the options ON Zone No ON The zone is an Instant Zone To deselect the option select a different zone delay type P40E Program Mode level Installer Remote by PC Factory Default Zon...

Page 17: ...e by PC Factory Default All ON Notes The SIREN output always locks out Programming Shortcuts Use 0E to turn all selections OFF Use MEMORY E to turn all selections ON RELATED OPTIONS P60E 4E Tamper Reset Lockout P78E Multiple alarm reports Assigning Zones to Areas Assign or remove zones that will operate in Area 1 and or Area 2 Programming sequence P45E Zone No E toggles the options ON and OFF for ...

Page 18: ...zones are already day zones Saves changes and returns to normal operating mode EnablesandDisablesDayMode This enables disables both Temporary and Permanent Day Zones Indication The HOME light flashes continuously when Temporary Day Mode is enabled OUTPUTS When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone wil...

Page 19: ...52E Zone No E toggles the options ON and OFF Zone No OFF The zone is not a 24hr zone Zone No ON The zone is a 24hr zone P52E Program Mode level Installer Remote by PC Factory Default All OFF Notes When a zone is selected as 24hr it is automatically removed from both Areas When a 24hr zone is assigned to an Area P45E or P46E it is no longer a 24hr zone Home Mode Zones Home Mode zones allow you to A...

Page 20: ...lections ON Reset output Zones Selects the zones to trigger the Reset output Programming sequence P54E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Reset output Zone No ON The zone will trigger the Reset output P55E Program Mode level Installer Remote by PC Factory Default all ON Programming Shortcuts Use 0E to turn all selections OFF Use MEMORY E to turn all ...

Page 21: ... Remote by PC Factory Default All OFF Programming Shortcuts Use 0E to turn all selections OFF Use MEMORY E to turn all selections ON Related Options P66E 1E Aux2 Zone Alarm Output AUX2 output Zones Selects the zones to trigger the AUX2 output on the main board This option selects which zones trigger AUX2 Once turned on by a zone alarm the output will remain on until the panel is reset disarmed Pro...

Page 22: ...ation Zone 8 is a normal alarm input 3E ON Zone 8 is the keyswitch input Entry beeps Keyswitch Arm Disarm Tamper Siren Lockout Auto Exclude zones Auto off keypad display Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P60E Various Options ON ON ON Keyswitch wiring If P60E 3E is enabled use a momentary action keyswitch with normally open contacts A momentary closed circuit across the resistor will to...

Page 23: ...zone is unsealed at the end of Exit Time the panel can either Exclude ignore that zone or immediately alarm If option P63E 7E is enabled the Siren output will give a 2 second burst at the end of Exit Time to indicate that the panel is armed with a zone s Auto Excluded Programming sequence P60E 6E toggles the option ON and OFF OFF Auto Exclude disabled instant alarm if unsealed at end of Exit Time ...

Page 24: ... Tamper Alarm to Siren output P61E 1E 4E program mode level Installer Remote by PC Factory Default 1E 4E ON Notes A Tamper Alarm is triggered by removing the PROG TAMP link on the main board Keypad Panic alarm output mapping This option selects which outputs will trigger when a Keypad Panic alarm occurs Programming sequence P61E 5E 8E toggles the options ON and OFF 5E ON Keypad Panic Alarm to Rese...

Page 25: ... 6E OFF Notes Allocate a user code to Area2 before programming Area2 shortcut arming If Area2 is armed with the shortcut and a user code is not assigned to Area2 then you will not be able to disarm the panel Siren burst on Auto Exclude This option enables the 2 second siren burst at the end of Exit Time to indicate that a zone s has been Auto Excluded This does not apply to manually excluded zones...

Page 26: ...iren output P63E 1E 4E program mode level Installer Remote by PC Factory Default 1E 2E ON 3E 4E OFF RELATED OPTIONS P64E 1E Brief Home alarm P63E 5E 8E program mode level Installer Remote by PC Factory Default 5E 6E ON 7E 8E OFF RELATED OPTIONS P64E 2E Brief Day alarm Day mode output mapping This option selects which outputs are triggered by alarms in Day Mode Programming sequence P63E 5E 8E toggl...

Page 27: ...hirp on arm disarm P64E 4E Program Mode level Installer Remote by PC Factory Default OFF RELATED OPTIONS P68E 8E Quiet Chirps P69E 5E Home Mode arming by Radio Key ON OFF buttons P69E 7E Home Mode by radio key Chirps Brief Day alarm Alarms in Day Mode will activate the programmed outputs while the zone is unsealed or they can activate the outputs for 2 seconds only This option also enables the Tem...

Page 28: ... Fire Alarm This option enables the operation of the keypad Fire Alarm A Fire alarm is activated by pressing the FIRE key followed by E The SIREN output changes to the FIRE sound If P75E 4E is enabled the fire alarm is reported by dialler to the central station Programming sequence P64E 7E toggles the option ON and OFF OFF No Keypad Fire Alarm ON Keypad Fire Alarm enabled P64E 7E Program Mode leve...

Page 29: ... programmed to output a momentary pulse on arming see P69E 1E Programming sequence P65E 2E turns the option ON The option is toggled off by selecting a different P65E option for Aux1 P65E 2E Program Mode level Installer Remote by PC Factory Default OFF RELATED OPTIONS P69E 1E Arm1 output pulses P65E 3E Program Mode level Installer Remote by PC Factory Default OFF Notes When this option is enabled ...

Page 30: ...IC button will TOGGLE the AUX2 output The output will operate independently of the panel s armed status ie disarming does not turn Aux2 off Programming sequence P66E 3E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 P66E 3E Program Mode level Installer Remote by PC Factory Default OFF Notes When this option is enabled the Radio Key s Panic button will n...

Page 31: ...reduced in volume to a quiet chirp Arm Disarm or Home Chirps must be enabled Programming sequence P68E 8E toggles the option ON and OFF OFF Quiet Chirps disabled ON Quiet Chirps enabled P68E 8E Program Mode level Installer Remote by PC Factory Default OFF RELATED OPTIONS P64E 4E Radio Key Chirps P69E 5E Home Mode by Radio Key ON OFF buttons AUX2 Output Fail To Communicate Output When this option i...

Page 32: ...ON and OFF OFF ARM2 output toggles ON ARM2 output pulses P69E 2E Program Mode level Installer Remote by PC Factory Default OFF Quiet Home Mode Siren This option selects the Quiet Siren sound in Home Mode The Quiet Siren sound is a continuous beep beep beep sound rather than the normal siren sound Programming sequence P69E 3E toggles the option ON and OFF OFF Normal siren sound in Home Mode ON Quie...

Page 33: ...MORY and the MEMORY display does not flash Programming sequence P69E 6E toggles the option ON and OFF OFF Mains Fail alarm operates normally ON Mains Fail alarm is disabled P69E 6E Program Mode level Installer Remote by PC Factory Default OFF Notes This does not affect Dialler mains fail reporting or saving to the History memory See page 18 for Home Mode operation Home Mode Chirps Allows 2 siren c...

Page 34: ... 1234 1234 P 70 E 0312341234 E To Clear a Telephone number To clear a telephone number enter the MEMORY key in place of the telephone number Example to clear a Telephone Number 1 press P70E MEMORY E P70E P71E Program Mode level Installer Remote by PC Factory Default None Notes If telephone number 2 is disabled all calls are made on telephone number 1 and the setting of P87E 1E has no effect When p...

Page 35: ... to the central station to verify th correct account number Note 2 Hex digit A is not allowed Client Account Number The Client Account number identifies a monitored system to the central station Programming sequence P72E existing account number is displayed one digit at a time ENTER NEW ACCOUNT No E new account number is displayed one digit at a time EXAMPLE To program Client Account No to be 1239...

Page 36: ...ONS P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E 3E Send Restoral on Disarm seal P82E 4E Send Restoral on Disarm always Report Multiple zone Alarms Zones selected for Multiple Zone Alarms will report each time the zone alarms and without a restore being sent The number of reports is a maximum of 15 The number of alarms sent for each Multiple Zone Alarm can be reduc...

Page 37: ...ce P82E 1E 4E toggles the option ON and OFF 1E ON Send Restoral immediately 2E ON Send Restoral after siren time 3E ON Send Restoral on Disarm seal 4E ON Send Restoral on Disarm always P82E 1E 4E Program Mode level Installer Remote by PC Factory Default 4E ON RELATED OPTIONS P76E Report zone restorals Send immediately Send after siren time Send after disarm seal Send after disarm always Option No ...

Page 38: ... 2 8hrs Therefore 6pm 8hrs 2am Programming sequence Press P84E The existing Time Before First Test Call will be displayed See note 3 Press NEW TIME E The new Time Before First Test Call will be displayed P84E Program Mode level Installer Remote by PC Factory Default 6 12hrs Notes 1 Enter a value from 1 to 99 2 If Test Calls are to start immediately then the value is set to 0 3 The Time Before Next...

Page 39: ... P86E 2E turns the option ON ON Contact ID format enabled P86E 2E Program Mode level Installer Remote by PC Factory Default ON Audible format For audible monitoring to any telephone or mobile phone The audible message consists of the warning words ALARM ALARM ALARM followed by the alarm message sent as a series of beeps The message is repeated for 4 times or until acknowledged by the receiving tel...

Page 40: ... attempts when sending reports OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re tries if unsuccessful ON allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if unsuccessful If all attempts fail the dialler waits for the next trigger event The previously unsuccessful report will be included in the new message When sending Test Calls the time betw...

Page 41: ...t sealed on arming will be reported as Auto Excluded Programming sequence P88E 8E toggles the option ON and OFF OFF No Auto Exclude Reports ON Auto Exclude Reports enabled P88E 8E Program Mode level Installer Remote by PC Factory Default ON RELATED OPTIONS P88E 7E Manual Exclude Reports Area1 open close reports Enables or disables sending of AREA1 Open Close reports The User ID of the code used is...

Page 42: ...ault ON Listen in to dialler This is a diagnostic feature to allow the installer to hear the dialler message and other telephone tones through a horn speaker To operate enable option P89E 3E Listen In is enabled for a minimum of 4 minutes after exiting Program Mode During Listen In the dialler message and other telephone tones can be heard through the Siren output at low volume while the dialler i...

Page 43: ...riodically 20secs tests the telephone line If the telephone line is not found the Line light starts flashing If the line fault continues for 2 minutes then the keypad beeps a warning and Aux2 is turned ON if that option is selected Programming sequence P89E 5E toggles the option ON and OFF OFF No Line Fail Monitor ON Line Fault Monitor enabled P89E 5E Program Mode level Installer Remote by PC Fact...

Page 44: ...elephone When the option is Off the panel will not answer incoming telephone calls preventing any type of remote access Programming sequence P90E 1E toggles the option ON and OFF OFF No Remote Access ON Remote Access enabled P90E 1E Program Mode level Installer Remote by PC Factory Default OFF RELATED OPTIONS P91E Required Rings Remote Access Remote event reporting Callback Mode Option No Descript...

Page 45: ... Installer Code Clear Radio Devices This option clears all Radio Devices assigned to zones 1 8 This option does not clear User Codes Programming sequence P95E Clears Radio Device Codes P95E Program Mode level Installer Remote by PC Factory Default not applicable These options allow selective restoring of various factory defaults For example you can default clear all the User Codes without affectin...

Page 46: ...Reset This function resets the microprocessor The effect is the same as powering down and powering up again Panel Reset operates in User and Installer program mode P88888888E eight 8 s Panel Reset Panel Model Software Version This function displays the panel software version and the model number Displayed in decimal format by the zone LEDs Example version 1 0 ECO8x is displayed by flashing 1 0 fol...

Page 47: ...ed cable or equivalent The shield can either be connected to the EARTH connection or left unconnected Leave the shield unconnected at the receiver end If the Radio Interface must be installed inside a metal enclosure the antenna wire should protrude outside the enclosure For best performance the antenna wire should be kept straight and not coiled shortened or extended The optional 100 046 Whip Ant...

Page 48: ...dio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first D If SUPERVISED SIGNALS have also been successfully recognised the T...

Page 49: ...xclude light is on Press 5E to enable that user code as a Radio Code Light 5 is on Press EXCLUDE E to exit Extra Options mode The Exclude light is off Press 1E The READY light will turn ON to indicate that the User Code is ready to accept the Radio Key If a code is already programmed the READY light will not turn on and a warning beep will sound To clear the code press 0E then go back to step 5 0E...

Page 50: ...n using NessComms software P130E Real Time Clock minutes Enter a value between 00 and 59 Default 00 minutes P131E Real Time Clock Hours Enter a value between 00 and 23 Default 00 hours P132E Real Time Clock Day of the month Enter a value between 01 and 31 Default 01 1st day of the month Ensure that the setting does not exceed the days in the current month The panel does not cross check this settin...

Page 51: ...Installer s notes 51 Ness ECO8x Control Panel Installation Manual ...

Page 52: ...18 1 110 01 034 k Exit Install mode ssss 18 1 306 01 035 k Internal Tamper ssss 18 q 137 01 041 k Keypad Tamper ssss 18 q 137 01 042 k Radio Sensor Tamper ssss 18 q 383 01 2zz k Radio Sensor Low Battery ssss 18 q 384 01 3zz k Mains Fail ssss 18 q 301 01 050 k Panel Battery Fail ssss 18 q 309 01 051 k Open ssss 18 1 402 aa 0dd k Force Open Cancel ssss 18 1 406 aa 0dd k Close ssss 18 3 402 aa 0dd k ...

Page 53: ...ssage is sent until all are acknowledged 6 If the alarm is not acknowledged then the panel will hang up and redial up to the maximum number of dial attempts 7 If the alarm is not acknowledged after all dial attempts then the keypad LINE light will flash continuously until the panel is next armed Acknowledge Tone The person receiving the call can then acknowledge the alarm by pressing the key on th...

Page 54: ...lude ON 3E Shortcut Home Mode ON 4E Shortcut SMOKE RESET OFF 5E Shortcut Area1 Arming ON 6E Shortcut Area 2 Arming OFF 7E Siren Burst on Auto Exclude ON 8E Exit Time x10 OFF u u u Options marked u can be programmed in User Program Mode All options can be programmed in Installer Program Mode u u Programming User Codes PIN programming and Extra Options for each user code User Code Table Extra Option...

Page 55: ...port Zone Restorals All on 36 P77E Report Misc Restorals All on 37 P78E Report Multiple Zone alarms none 36 P81E Telephone No Callback none 34 Option Description Default Page P82E 1E Send RESTORAL report immediately OFF 37 2E Send RESTORAL after siren time OFF 3E Send RESTORAL after Disarm seal OFF 4E Send RESTORAL after Disarm always ON P83E Test Call Interval 84 168hrs 38 P84E Time before First ...

Page 56: ...diated RF Immunity Electrical Fast Transient burst Surge Immunity Conducted RF Immunity Voltage Dips and Interruptions Mains Supply Variations AS NZ CISPR 22 2002 Class B Electromagnetic Radiation Terminal Disturbance Voltage EN61000 6 3 2001 Harmonic Current Emissions Voltage fluctuations and Flicker TELECOM TBR21 EU PTC200 NEW ZEALAND TELECOM AS ACIF S002 AUSTRALIA SAFETY EN60950 2000 inc Countr...