ZonE to oUtpUt mappIng
When a zone alarms, it can turn on any or all of these outputs: Sonalert, Strobe,
Siren, Reset, AUX2.
The programming is selected with options P4E – PE. Simply set the zone
number to the output to select it. The zone LED will indicate if the zone is se-
lected.
The Tamper Input and the Keypad Panic can be mapped to the Reset, Strobe,
Sonalert and Siren by using option P1E.
MAPPING ZONES TO OUTPUTS
ZONEs
Option No.
description
1 2 3 4 8
p54E
REsEt Zones
ON ON ON ON ON ON ON ON
p55E
stRObE Zones
ON ON ON ON ON ON ON ON
p56E
sONAlERt Zones
ON ON ON ON ON ON ON ON
p57E
sIREN Zones
ON ON ON ON ON ON ON ON
p59E
AUX2 Zones
Zone to Output mapping
applies to zones when the panel is
in the Armed or 24hr state.
For HOmE mOdE and dAy mode
Output mapping – see Option
p63E 1E–8E, page 26.
P4E
PROGRAM MODE LEVEL
Installer, Remote by pC.
FACTORy DEFAULT
All ON.
PROGRAMMING ShORTCUTS
Use
0E
to turn all selections OFF.
Use MEMORY E
to turn all selections ON.
rEsEt oUtpUt ZonEs
selects the zones to trigger the Reset output.
PROGRAMMING SEQUENCE:
P54E [Zone No]E
toggles the options ON and OFF
[Zone No] oFF: The zone will not trigger the Reset output
[Zone No] oN: The zone will trigger the Reset output
PE
PROGRAM MODE LEVEL
Installer, Remote by pC.
FACTORy DEFAULT
all ON.
PROGRAMMING ShORTCUTS
Use
0E
to turn all selections OFF.
Use MEMORY E
to turn all selections ON.
strobE oUtpUt ZonEs
selects the zones to trigger the strobe output.
PROGRAMMING SEQUENCE:
P55E [Zone No]E
toggles the options ON and OFF
[Zone No] oFF: The zone will not trigger the Strobe output
[Zone No] oN: The zone will trigger the Strobe output
PE
PROGRAM MODE LEVEL
Installer, Remote by pC.
FACTORy DEFAULT
All ON.
PROGRAMMING ShORTCUTS
Use
0E
to turn all selections OFF.
Use MEMORY E
to turn all selections ON.
KEypaD sonalErt ZonEs
selects the zones which will sound the Keypad sonalert (beeper).
PROGRAMMING SEQUENCE:
P56E [Zone No]E
toggles the options ON and OFF
[Zone No] oFF: The zone will not trigger the Keypad Sonalert
[Zone No] oN: The zone will trigger the Keypad Sonalert
20
N
ess
eCO8
x
C
ONtrOl
P
aNel
– I
NstallatION
M
aNual