P120e 1e
relAteD oPtions
P60e 2e, 3e Keyswitch options.
P120e 2e
note.
This option enables Radio Key Home
Arming chirps regardless of the state of
P64e 4e (Radio Key siren chirps).
relAteD oPtions
P64e 6e Strobe Flash on Home Arming
by Radio.
PROGRAMMING SeQUeNCe:
P120e [1e–6e]
Turns options on or off.
lAtCHeD keysWitCH
This option enables the use of a latched, (2 position on/off), keyswitch. Keyswitch
operation must first be enabled using options P60e 2e, 3e, page 24.
note: enAbling lAtCHeD keysWitCH DisAbles All otHer metHoDs oF
Arming AnD DisArming (keyPAD, rADio key, CArD).
oFF: no Latched Keyswitch. (Factory default). on: Latched Keyswitch enabled.
siren CHirP on Home Arming by rADio
This option enables siren chirps when arming and disarming Home Mode with a Radio
Key.
oFF: no Home arm chirps. (Factory default). on: Home arm chirps enabled.
ProgrAm moDe leVel
Installer mode or NessComms.
Option No.
Description
Default
P120e
1e
latched keyswitch input
OFF
2e
Siren Chirp on Home Arming by Radio
OFF
3e
Radio Key AUX arms Home Monitor
OFF
4e
Keyswitch ARM only
OFF
5e
Keyswitch Disarm only
OFF
6e
Smart Beep
OFF
7e
entry Delay Timer1 x10
OFF
8e
Area2 Disarm by Keyswitch Allowed
OFF
oUtPUt exPAnDer Zones
This selects the zones that will be output whenever the zone is unsealed. When the
zone reseals the output automatically goes off.
Additionally if a zone is also selected in P119 (to zone latch) then an output will only
occur whenever a zone is in alarm and is also unsealed. In this case when the zone
reseals the output automatically goes off again. A further zone unseal will turn the zone
expander output On again.
PROGRAMMING SeQUeNCe:
P118e 1e-16e
toggles the options ON and OFF
[Zone no]e oFF: output expander disabled for that zone
[Zone no]e on: output expander enabled for that zone
P118e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All OFF: No Output expander zones.
notes
• Selecting a zone in both P118 & P119
options effectively gives pulsed outputs
whenever that zone alarms.
oUtPUt exPAnDer AlArm Zones
This selects the zones that will be output whenever the zone is latched into alarm. The
output goes off only when the alarm system is reset.
Additionally if a zone is also selected in P118 (to zone follow) then an output will only
occur whenever a zone is in alarm and is also unsealed. (See P118 above).
PROGRAMMING SeQUeNCe:
P119e 1e-16e
toggles the option ON and OFF
[Zone no]e oFF: output expander zone alarm disabled for that zone
[Zone no]e on: output expander zone alarm enabled for that zone
P119e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Output expander zone latch.
ZONeS 1–8
(D8 & D16)
ZONeS 9–16
(D16)
Option No. Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
P118e
OUTPUT eXPANDeR ZONeS
P119e
OUTPUT eXPANDeR AlARM ZONeS
56
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g