oPerAtion sUmmAry
OPeRATION
by
keyPAD
by
rADio key
by
ACCess CArD
or
Fob
to
Arm
The panel must initially be
disarmed.
Press
+
(If the Arming Shortcut is enabled, P62e 5e)
Press the ON button once.
Present a Card or Fob
twice. (if P301e 2e is
on).
Or, present a Card
or Fob once + press
button. (if P301e 3e
is on).
or press
+
[User Code]
+
or press
[User Code]
+
(If Code Only Arming has been enabled for
that user code. extra Option 4e)
to
DisArm
To disarm and/or reset alarms.
Press
[User Code]
+
Press the OFF button once.*
Present a Card or Fob
once. (if P301e 4e is
on).
to arm
Home moDe
Area1 must initially be
disarmed.
Home Mode can be used if
the panel is fully disarmed or if
only Area2 is armed, see page
20 for more information.
Press
+
(If the Home Shortcut is enabled, P62e 3e)
Press either the OFF
button or the ON button
twice within 4 seconds.
(P69e 5e must be on).
Or press the AUX but-
ton once. (If P120e 3e
is on). RK4 radio key
only.
or press
+
[User Code]
+
Radio Key Home Arm chirps can be enabled by
P120e 2e. Radio Key Home Arm strobe flash can
be enabled by P64e 6e, (off by default).
PAniC
alarm
Press
keys together
Press and hold the PANIC
button for at least 4 sec.
If P68e 1e Double Press
Radio Panic is enabled,
press and hold twice for 4
sec.
or press
+
[User Code]
+
or press
+
(If Keypad Panic Shortcut is enabled, P62e 4e)
keyPAD DUress
Keypad Duress allows the user
to send a silent duress report
while disarming, (if the system
is being monitored by a central
station).
Press
[5, 6, 8 or 9]
+
[User Code]
+
Add one these digits in front of a user code when disarming.
This sequence will disarm the panel and send a Duress report by dialler to the central station.
(Report Keypad Duress must be enabled, P75e 1e)
exClUDe Zones
e e can only
be used when the panel is
disarmed.
e CODe + e can be
used anytime.
Press
+
(If the exclude Shortcut is enabled, P62e 2e)
then
[Zone No.]
+
[Zone No.]
+
(enter the zone number/s to be excluded.)
then press
to exit exclude mode
The exclude light flashes constantly while zones are excluded. excluded zones are automatically
Included next time the panel is disarmed.
oPerAte AUx
oUtPUts
The AUX outputs must be
enabled for operation by
keypad. See P141e 4e, P142e
4e, P143e 4e, P144e 4e.
Press
to turn ON or PUlSe
AUx1.
Press
to turn OFF.
Press
to turn ON or PUlSe
AUx2.
Press
to turn OFF.
Press
to turn ON or PUlSe
AUx3.
Press
to turn OFF.
Press
to turn ON or PUlSe
AUx4.
Press
to turn OFF.
* If a user code is assigned to a radio key and has extra Option 4e enabled, (Code Only arming), then pressing OFF toggles the panel arm/disarm state.
temPorAry DAy Zone
(tDZ)
operation
While remaining in normal operating mode, the user can add and remove Temporary Day Zones and enable/disable day zone operation.
The panel must initially be
disarmed.
P64e 2e must be on to enable
the use of Temporary Day
Zones.
See page 20 for more
information on Temporary Day
Zones.
Press
+
To enter TDZ Selection Mode.
then press
[Zone No.]
+
To select one or more zone to be Temporary Day Zones.
then press
To save changes and exit TDZ Selection Mode.
Press
+
To enable/disable TDZ operation.
Temporary Day Zone mode enabled is indicated by the Home icon flashing.
11
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Summary of Contents for D16xD
Page 94: ...NOTES ...