Installation & Programming Manual

D8xD / D16xD AlArm Control PAnel

Available with Navigator, Saturn or 

KPX keypad options

Deluxe edition with expanded AUX outputs, Voice alarms,  

Voice prompts, enhanced modem, Real time clock.

D8x/D16x DelUXe

Version v8.4

Document 890-017

Auto-Time 

Automation

8 x AUX 
Outputs

Various 

Keypad 

Options

Operation by 

Smartphone / 

Internet

Operation by 

Telephone

Voice Alarms 

& Prompts

Access 
Control 

onboard

Powerful 
Wireless 

Options

C-BUS 

Compatible 

using Ness 
MiniCentral

Area 

Partitioning

Dual Voltage

17VAC & 20VDC

8 or 16 

Hardwired or 

Wireless zones

easy 

Programming  

via Keypad

Fast 

Programming  

via PC

On-Site 

Programming  

via PD Tool

Free 

NessComms 

Installer Software

Back To Base 

or Voice Dialler 

Monitoring

Adjustable 

Vibration Inputs 

on all Zones

AUX

8

16

Summary of Contents for D16xD

Page 1: ...8 x AUX Outputs Various Keypad Options Operation by Smartphone Internet Operation by Telephone Voice Alarms Prompts Access Control onboard Powerful Wireless Options C BUS Compatible using Ness MiniCentral Area Partitioning Dual Voltage 17VAC 20VDC 8 or 16 Hardwired or Wireless zones Easy Programming via Keypad Fast Programming via PC On Site Programming via PD Tool Free NessComms Installer Softwar...

Page 2: ...dio accessories are installed Ness radio products are sophisticated low power devices however the presence of in band radio signals high power transmissions or interference caused by electrical appliances such as Mains Inverters Wireless Routers Cordless Phones Computers TVs and other electronic devices may reduce radio range performance While such occurrences are unusual they are possible In this...

Page 3: ... Siren Chirp Flash options 46 Other reports 47 Enable Test Calls 48 Mains Report Delay 48 Listen in to dialler 48 Swinger Shutdown 49 Line Fault Monitor 49 Remote access options 50 51 Required Rings 52 No Memory Warning zones 52 Factory Defaults Clear Radio Devices 53 Clear Memory 53 Clear Panel Options 53 Clear User Codes 53 Output Expander options 54 56 Aux outputs Aux1 output options 58 59 Aux2...

Page 4: ...ing by keypad or NessComms software New modem chip allows common modems to be used for upload download in 300baud mode All programming data is permanently stored in a non volatile memory All inputs and outputs are heavily protected against lightning and high voltage supply transients High efficiency DC power supply Optional output expander DIALLER Full remote upload download by PC and modem using ...

Page 5: ...rvice panels Use Ness PD to store your default programming for even faster commissioning on site Fully Clipsal approved C Bus Enabled Product Controls up to 255 individual C Bus lights or outputs Includes full dimming On Off and toggle commands True 2 way communications on the C Bus network Connects directly onto C Bus without the need for ad ditional hardware such as a PCI Interface Many D16X eve...

Page 6: ... Ness panels are supplied with 2k2 1 tolerance Metal Film resistors Colour code Red Red Black Brown Brown TELEPHONE LEAD Supplied Connect to Mode3 socket Lead shown is for Australia only BATTERY CONNECTION For 12V 7Ah backup battery BAT210 RECEIVER Header for connecting optional Radio Interface AUX Aux outputs 1 4 SERIAL Rs232 serial port READER Connection for up to 3 Ness Weigand readers OUT 12V ...

Page 7: ...time P29E or whenever the panel is reset whichever comes first This output is protected by an Automatic Reset fuse STR A latched 12VDC output for connecting strobe lights This output will reset after 72 hours 3 days or when the panel is disarmed D8 D16 versions prior to V4 5 allow indefinite strobe operation until the panel is reset A maximum of 2 x 1 Watt Strobes Ness Part No NOI300 can be connec...

Page 8: ...l 12V outputs 12V Red CLK White DAT Blue T COM Black Polarity is not important for this output BOX TAMPER SWITCH White N C contacts Connect to J1 1 Listen Out 2 not used 3 Common 4 12V out 8 ohm spkr pins 1 3 and connection for output expander s Telephone lead Australia only Connect to Mode3 socket END OF LINE RESISTORS The default end of line resistor value is 2k2 2200 Ohms The EOL value is fully...

Page 9: ... low 0v when movement is detected Additional 12V terminal 0V 12V AUX4 AUX3 AUX2 AUX1 NO C AUX1 NC NO C AUX2 NC NO C AUX3 NC NO C AUX4 NC 106 013 Relay Board Provides 4 relay outputs suitable for switching low voltage accessories Connect up to one additional expander OUT 12V In 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IN 106 011 Output Expander Provides 16 programmable open collector outputs See page...

Page 10: ...displayed while the button is held down Display Test can be activated at any time either in operating mode or any program mode Number of Keypads Up to 3 LCD keypads can be connected to a panel Cable Length The maximum allowable cable length is 100m total cable length to all keypads The instructions on this page relate to Ness Saturn and KPX keypads Refer to the Ness Navigator user s manual for ope...

Page 11: ...digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler to the central station Report Keypad Duress must be enabled P75E 1E Exclude Zones Exclude E can only be used when the panel is disarmed Exclude CODE E can be used anytime Press If the Exclude Shortcut is enabled P62E 2E then Zone No Zone No Enter the zone number s to be excluded th...

Page 12: ...ller Program Mode Program light will flash Default Installer Code is 000000 3 P 2 0 1 E Selects the option for User Code 1 The existing code will be displayed 4 _ _ _ _ E Enter your new PIN code followed by E Keypad codes can be 3 to 6 digits in length 5 _ _ _ _ E Enter your new PIN code again The new code will be displayed 6 P 8 6 E 2 E Turns on option P86E 2E Enables Contact ID format 7 P 7 0 E ...

Page 13: ...Installer Program Mode PROGRAM light is FLASHING How to EXIT Program Mode 1 Press then Exits directly to Operating Mode PROGRAM light is OFF Factory Defaults Master Code 123 Installer Code 000000 NESS PD 106 017 D8X D16X PORTABLE DOWNLOAD NESS PD 106 017 D8X D16X PORTABLE DOWNLOAD From Panel to PD From PD to Panel 1 The panel should be in Installation Program Mode 2 Connect the NessPD to the READE...

Page 14: ...d code does not need to be deleted first The new code will overwrite the old code Deleting Keypad Codes To delete a User Code without programming a new code press the MEMORY key in place of the code Example To delete User Code 2 press P202E MEMORY E A keypad code only needs to be deleted if you re not replacing it with a new code Arm Only Codes Arm Only is an extra option for user codes See next p...

Page 15: ... are armed they can be disarmed If in Home mode the action is to exit Home mode Codes selected for Code Only Arming and not assigned to any areas are automatically REX codes See page 82 5E Radio Code Enables selected user codes as Radio Codes for operation by Ness Radio Key or Radio Keypad Page 74 how to program Radio Codes 6E Reader Code 1 Enables user codes as Access Control codes assigned to Re...

Page 16: ...e EXAMPLE To program Entry Delay Time2 to be 600 seconds P27E 60E P27E Program Mode level User Installer mode or NessComms Factory Default 6 60 seconds Notes Programmable from 10 990 seconds Exit Delay Time The Exit Delay Time is the time given to secure and depart the premises after the panel is armed All zones except 24hr zones are inactive during the Exit Delay time The Exit Delay Time setting ...

Page 17: ... Zone sensitivity is adjusted by toggling zones ON in options P30E to P36E P30E is Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 36E are the options for the 6 levels of vibration sensitivities P31E is the most sensitive setting Programming sequence P 30 38 E zones are displayed Zone No E EXAMPLE To program zones 2 and 3 to be Medi...

Page 18: ...ons ON instant Zones Instant Zones operate only in the Armed state When Armed at the expiry of exit time Instant Zones will activate assigned outputs immediately when triggered Programming sequence P40E Zone No E turns the options ON Zone No ON The zone is an Instant Zone To deselect the option select a different zone type in the DELAY GROUP P40E Program Mode level Installer mode or NessComms Fact...

Page 19: ...ng sequence P44E Zone No E toggles the options ON and OFF P44E Zone No E OFF The zone is not a Lockout zone P44E Zone No E ON The zone is a Lockout zone P44E Program Mode level Installer mode or NessComms Factory Default All ON All zones are Lockout zones Notes The SIREN output always locks out 0E will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P60E 4E Tamper Rese...

Page 20: ...keypad as an unsealed zone KPX CHIME The KPX keypad has a special two tone chime which can be enabled in place of the default beep warning tone See P126E 4E Aux 2 Option When the Temporary Day Zone feature is enabled the installer option P63E 6E selects Aux 2 output instead of the strobe output This allows a remote warning device such as a buzzer to be connected for day zone warning This may be ne...

Page 21: ...per input is always a 24hr zone For silent 24hr zones deselect the zone s from options P54E P57E Reset Strobe Sonalert Siren To change a 24hr zone to any other zone type the zone must also be re assigned to an AREA P45E or P46E Home Zones Home zones allow you to Arm selected zones while others are ignored Typically used for perimeter zones such as windows and doors while you are at home For exampl...

Page 22: ... Reset output Notes 0E will turn all selections OFF MEMORY E will turn all selections ON Reset output Zones Selects the zones to trigger the Reset output Programming sequence P54E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Reset output Zone No ON The zone will trigger the Reset output P55E Program Mode level Installer mode or NessComms Factory Default all ON...

Page 23: ...P123E 1E to enable the ouput Once turned on by a zone alarm the output will remain on until the panel is reset disarmed Programming sequence P58E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger AUX1 3 output s Zone No ON The zone will trigger the AUX1 3 output s P59E Program Mode level Installer mode or NessComms Factory Default All OFF No zones trigger AUX 2 or 4 No...

Page 24: ...itch wiring If P60E 2E or 3E are enabled use a momentary action keyswitch with normally open contacts A momentary closed circuit across the resistor will toggle panels modes Open circuit the resistor to trigger Panic if required Panic on this input is disabled if P120E 1E is enabled If P120E 1E is enabled use a latching keyswitch When the resistor is sealed panel is disarmed If the resistor is uns...

Page 25: ... The touch screen display will go blank Touch to restore Tamper Siren Lockout This option programs the Tamper input to Lockout i e cause the Siren Reset outputs to sound only once while the panel is armed Programming sequence P60E 4E toggles the option ON and OFF OFF Tamper Reset Lockout disabled ON Tamper Reset Lockout enabled Duress To Reset Output Keypad Duress is normally a silent alarm This o...

Page 26: ...rm occurs Programming sequence P61E 5E 8E toggles the options ON and OFF 5E ON Keypad Panic Alarm to Reset output 6E ON Keypad Panic Alarm to Strobe output 7E ON Keypad Panic Alarm to Keypad Sonalert output 8E ON Keypad Panic Alarm to Siren output P61E 5E 8E program mode level Installer mode or NessComms Factory Default 5E 8E ON Panic alarm triggers all outputs Notes A Keypad Panic Alarm can be ca...

Page 27: ...that Area then it will always remain armed You will then need to enter program mode on power up and assign codes to Areas Siren burst on Auto Exclude This option allows the disabling of the 2 second siren burst at the end of Exit Time which indicates a zone s has been Auto Excluded Programming sequence P62E 7E toggles the option ON and OFF OFF Siren burst on Auto Exclude disabled ON Siren burst on...

Page 28: ...8E OFF RELATED OPTIONS P64E 2E Brief Day alarm Day mode output mapping This option selects which outputs are triggered by alarms in Day Mode Programming sequence P63E 5E 8E toggles the options ON and OFF 5E ON Day Mode to Reset output 6E ON Day Mode to Strobe output If Brief Day Alarm is enabled P64E 2E then this option sends day alarms to the AUX2 output 7E ON Day Mode to Keypad Sonalert output 8...

Page 29: ... mapping Arm disarm chirps If this option is selected the Siren output will Chirp when the panel is armed and disarmed with the Keyswitch input prox cards or Radio Keys This option applies to siren chirps the strobe output always flashes when arming disarming by the above methods Home arming chirps are enabled separately by option P120E 2E The siren output will make 1 Chirp on Arming and 3 Chirps ...

Page 30: ...he option ON and OFF OFF No strobe flash ON Strobe flash enabled P64E 6E Program Mode level Installer Remote by PC Factory Default OFF No strobe Notes This is not related to strobe flash on arming and disarming area 1 or 2 by radio key which always flashes the strobe on arm and disarm RELATED OPTIONS P69E 5E Home Mode arming by radio key P120E 2E Siren Chirp on Home Arming by Radio 30 Ness D8x D16...

Page 31: ... Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device has not been removed from radio range and is in working order A non SUPERVISion enabled Radio PIR will transmit signals to the panel only when it has detected an event Obviously there is no guaranteed signal period In either case when the allowed time limit is exceeded then a WARNING is first given if progra...

Page 32: ...N and OFF OFF Supervision Strobe output disabled ON Supervision Strobe output enabled P66E 2E Program Mode level Installer mode or NessComms Factory Default OFF Supervision Strobe output disabled RELATED OPTIONS P65E Supervised Zones Zone Supervision alerts Keypad SONALERT Setting this option turns the Keypad Sonalert ON when a SUPERVISED Zone alert occurs The Keypad Sonalert remains ON until any ...

Page 33: ...Radio Zone Supervision Programming sequence P66E 5E toggles the option ON and OFF OFF Radio Zone Supervision enabled ON Wired Zone Supervision enabled P66E 5E This option is available in D8x D16x V5 2 and later Program Mode level Installer mode or NessComms Factory Default OFF Radio Zone Supervision enabled RELATED OPTIONS P65E Supervised Zones P66E 1E 4E Supervision Alerts P66E 5E Wired Zone Supe...

Page 34: ...mode or NessComms Factory Default OFF Single Press Radio Panic Auto Re Arm Auto Re Arm checks that you have entered the premises after disarming After disarming the panel will wait for the same time set for Entry Delay If all zones remain sealed the panel will re arm This is most useful when used with radio keys where the OFF button might be accidentally pressed after you have armed and are leavin...

Page 35: ...nsealed zone warning is inactive if P64E 4E Arm Disarm Chirps is enabled regardless of the status of P68E 5E OK READY DISPLAY OPTION When the option of OFF the OK READY icon will display even if Entry Delay zones are unsealed This is useful in cases where the keypad location is covered by a PIR with entry delay When this option is ON all zones including Entry Delay zones must be sealed for the key...

Page 36: ... Mode Flash strobe on medical alarm This option enables the strobe output when a medical alarm is triggered This is to make the house visible to the ambulance The strobe will reset after 72 hours or when a valid code is entered Programming sequence P69E 3E toggles the option ON and OFF OFF Strobe does not flash on medical alarm ON Strobe flashes on medical alarm P69E 3E Program Mode level Installe...

Page 37: ...er mode or NessComms Factory Default OFF Mains Fail alarm normal Notes This does not affect Dialler mains fail reporting or saving to the History memory or operation of the Mains Fail output on the Output Expander Does not apply to Navigator keypad See page 20 for Home operation Beeps During Exit Delay Fully Armed Mode This option gives an audible warning during Exit Delay The sonalert will beep s...

Page 38: ...rogramming sequence P70E existing telephone number is displayed one digit at a time ENTER NEW TELEPHONE No E new telephone number is displayed one digit at a time EXAMPLE To program Telephone No 1 to be 03 1234 1234 P 70 E 0312341234 E To Clear a Telephone number To clear a telephone number enter the MEMORY key in place of the telephone number Example to clear a Telephone Number 1 press P70E MEMOR...

Page 39: ...al as required by some central stations Use the following keys to enter the hex digits B C D E or F HEX DIGIT Key entry Displayed on LCD display B Key 11 C ARM Key 12 D HOME Key 13 E EXCLUDE Key 14 F MEMORY key 15 HEX Account Numbers Notes Note 1 If using the Ness LED keypad for programming the Hex digits will not be displayed but are still programmed Note 2 Hex digit A is not allowed Note 3 Enter...

Page 40: ...report each time the zone alarms and without a restore being sent The number of reports is a maximum of 15 The number of alarms sent for each Multiple Zone Alarm can be reduced to 3 by using the swinger shutdown option P89E 4E Zones not selected report only once until reset by an opening or a valid code Programming sequence P78E Zone No E toggles the option ON and OFF Zone No E OFF Multiple Zone A...

Page 41: ... Disarm seal 4E ON Send Restoral on Disarm always P82E 1E 4E Program Mode level Installer mode or NessComms Factory Default 4E ON Always send Restoral on Disarm RELATED OPTIONS P76E Report zone restorals Alarm Default Restoral Default D8 D16 Alarm Restoral Alarm Restoral Duress ON P75E 1E P77E 1E P75E 1E P77E 1E Medical ON P75E 2E P77E 2E P75E 2E P77E 2E KP Panic KS Panic ON ON P75E 3E P77E 3E P75...

Page 42: ... 1am Enter P84E 4E 4 x 2 8hrs Therefore 5pm 8hrs 1am B Existing Installation To reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at 6pm enter P84E 4E 4 x 2 8hrs Therefore 6pm 8hrs 2am Programming sequence Press P84E The existing Time Before Next test call will be displayed See note 3 Press N...

Page 43: ...zz k Radio Sensor Low Battery ssss 18 q 384 01 3zz k Mains Fail ssss 18 q 301 01 050 k Panel Battery Fail ssss 18 q 309 01 051 k Open Disarm ssss 18 1 402 aa 0dd k Force Open Cancel ssss 18 1 406 aa 0dd k Close Arm ssss 18 3 402 aa 0dd k Closing Extended ssss 18 3 464 aa 0dd k Test Report ssss 18 1 602 01 063 k Zone 1 16 Manual Exclude ssss 18 q 573 aa 001 016 k Zone 1 16 Auto Exclude ssss 18 q 38...

Page 44: ...E Program Mode level Installer mode or NessComms Factory Default OFF Audible VOICE format For Audible Monitoring to any telephone or mobile phone Zone alarms are sent in Audible VOICE format The message is repeated for 45 seconds or until kissed off by the receiving telephone Programming sequence P86E 4E turns the option ON ON Audible VOICE format enabled P86E 4E Program Mode level Installer mode ...

Page 45: ...ul report will be included in the new message When sending Test Calls the time between dialling attempts increases to 60 minutes for the second round of dialling If a Test Call is unsuccessful after the first round of calls are made another call is made after 5 minutes If this call fails then subsequent calls are made every hour up to the maximum number of calls Programming sequence P87E 4E toggle...

Page 46: ...the Arming report Programming sequence P88E 3E toggles the option ON and OFF OFF No Siren Chirp on kiss off ON Siren Chirp on kiss off enabled P88E 3E Program Mode level Installer mode or NessComms Factory Default OFF No Siren Chirp on kiss off RELATED OPTIONS P88E 4E Flash Strobe on kiss off Strobe Flash on kiss off Selects a 2 Second Strobe on a successful Closing report This is used to give vis...

Page 47: ...ing ON Closing Reports sent at end of Exit Time P88E 6E Program Mode level Installer mode or NessComms Factory Default OFF Closing Reports sent on Arming RELATED OPTIONS P88E 1E AREA1 Open Close reports P88E 2E AREA2 Open Close reports Manual Exclude Report Enables Manual Exclude Reports for zones Exclude Reports for 24hr zones are sent on exiting EXCLUDE mode Programming sequence P88E 7E toggles ...

Page 48: ...the main board This method required no programming options to be set the LISTEN pins are always active Method 2 This method requires option P89E 3E to be turned on Listen In is enabled for a minimum of 4 minutes after exiting Program Mode During Method 2 Listen In the dialler message and other telephone tones can be heard through the Siren output at low volume while the dialler is sending reports ...

Page 49: ...y multiple alarms reported to the Central station in cases for example where a door is swinging in the wind This option only applies to zones enabled to Report Multiple Zone Alarms RELATED OPTIONS P78E Report Multiple Zone Alarms Line Fault Monitor When this option is enabled the telephone line is regularly tested If the telephone line is not found the Line light will commence flashing Programming...

Page 50: ... by telephone P90E 2E Program Mode level Installer mode or NessComms Factory Default OFF Second Call Mode enabled Notes If Callback is enabled P90E 8E is on then First Call mode is disabled RELATED OPTIONS P91E Required Rings Enable First Call Mode For remote access the panel can answer incoming telephone calls on either the First or Second Call First Call Mode The panel answers a telephone call a...

Page 51: ...g and alarm states and Remote Keypad Operation including arming disarming Requires NessComms V5 2 and later Programming sequence P90E 6E toggles the option ON and OFF OFF No Remote Status Reporting ON Remote Status Reporting enabled P90E 6E Available in D8x D16x V5 6 and later Program Mode level Installer mode or NessComms Factory Default OFF No Remote Status Reporting Remote AUX Control Enables t...

Page 52: ...E Programmable from 1 to 24 rings Enter a value between 1 and 24 Installer s TIP Rings are counted in the panel as a ring signal followed by a period of silence For instance on the first ring the count is not registered until the second ring starts Programming sequence P91E existing Required Rings value is displayed one digit at a time ENTER NEW VALUE E new Required Rings value is displayed one di...

Page 53: ... P98E Program Mode level Installer mode or NessComms Factory Default User Code 1 123 All other codes blank Notes This option DOES NOT clear the Installer Code Clear Radio Devices This option clears all Radio Devices assigned to zones 1 8 or 1 16 This option does not clear User Codes Programming sequence P95E Clears Radio Device Codes P95E Program Mode level Installer mode or NessComms Factory Defa...

Page 54: ...e that the USER CODE does not have to be assigned to an AREA for this to work If P117E 6E is ON then the ARM DISARM buttons on Radio Keys do not change the Code13 15 outputs on the output expander Only the AUX button works pulsing ON the Code13 15 output for the time set by P145E Option No Description Default P117E 1E Enable Output Expander OFF 2E Expander Output Format A B OFF 3E Day Zone followe...

Page 55: ...clude enabled Expander Output Format C Use this option along with option P117E 2E to configure the output expander outputs as per the output tables Three different combinations of outputs are available for either a single or dual output expanders Programming sequence P117E 5E toggles the option ON and OFF User Code Toggle or Pulse Selecting this option changes the User Code 13 to 15 operations to ...

Page 56: ...ditionally if a zone is also selected in P119 to zone latch then an output will only occur whenever a zone is in alarm and is also unsealed In this case when the zone reseals the output automatically goes off again A further zone unseal will turn the zone Expander output On again Programming sequence P118E 1E 16E toggles the options ON and OFF Zone No E OFF Output Expander disabled for that zone Z...

Page 57: ...ust first be enabled using options P60E 2E 3E page 24 OFF Keyswitch arms and disarms Factory default ON Keyswitch disarms only Keyswitch Arm Only Converts the use of keyswitch operation using P60E 2E and 3E to only arm either from Area or Home mode Keyswitch operation must first be enabled using options P60E 2E 3E page 24 OFF Keyswitch arms and disarms Factory default ON Keyswitch arms only Smart ...

Page 58: ...ption can be on P121E 1E Zone Alarms to Aux1 RELATED OPTIONS P58E Aux1 3 zones With this option ON zones selected in P58E will turn on Aux1 when they go into alarm The Aux1 output turns off when the panel is disarmed reset P121E 2E Zone Supervision Alarms to Aux1 RELATED OPTIONS P65E P66E P67E Radio Supervision Setting this option turns the AUX1 output ON when a SUPERVISED RADIO alarm is triggered...

Page 59: ...pad toggle AUX1 When this option is on AUX1 is turned ON or PULSED with the keypress 11 Left hand STAR button AUX1 is turned OFF with the keypress 11 Right hand STAR button P141E 5E Telephone remote Control of AUX1 Notes Remote operation by telephone procedure as detailed in the user and installation manuals must be followed before access is allowed This includes entering a valid user code RELATED...

Page 60: ...on on Only one option can be on P122E 1E Zone Alarms to Aux2 RELATED OPTIONS P59E Aux2 zones With this option ON zones selected in P59E will turn on Aux2 when they go into alarm The Aux2 output turns off when the panel is disarmed reset P122E 2E Zone Supervision Alarms to Aux2 RELATED OPTIONS P65E P66E P67E Radio Supervision Setting this option turns the AUX2 output ON when a SUPERVISED RADIO alar...

Page 61: ...ed This includes entering a valid user code RELATED OPTIONS P90E 5E Enable remote Aux control When this option is on AUX2 is turned ON or PULSED with the telephone keypress 22 AUX2 is turned OFF with the telephone keypress 22 Feedback tones heard by phone 3 beeps The AUX has been turned ON or is already ON 1 beep The AUX has been turned OFF or is already OFF 1 long beep Error Remote AUX operation ...

Page 62: ...s and alarms If the AUX3 output does not behave as expected please check all related options such as AutoTimers and P143E options To Program 1 Press P123E 2 Press 1E 8E to turn an option on Only one option can be on P123E 3E Enable AUX3 for AutoTimer Available in D8x D16x V8 and later RELATED OPTIONS P370E to P389E AutoTimers When this option is on AUX3 is enabled for use by AutoTimer P123E 4E Rad...

Page 63: ...Home Armed to AUX3 Turns on AUX3 while armed in Home mode P143E 4E Keypad toggle AUX3 When this option is on AUX3 is turned ON or PULSED with the keypress 33 Left hand STAR button AUX3 is turned OFF with the keypress 33 Right hand STAR button P143E 5E Telephone remote Control of AUX3 Notes Remote operation by telephone procedure as detailed in the user and installation manuals must be followed bef...

Page 64: ...nables the Aux4 output to duplicate all keypad beeps including keypress beeps This is useful in cases where for example entry beeps or other keypad beeps need to be heard in more than one location on the premises Adding an additional keypad would also achieve the same result P124E 3E Enable AUX4 for AutoTimer Available in D8x D16x V6 and later RELATED OPTIONS P370E to P389E AutoTimers When this op...

Page 65: ...llowed before access is allowed This includes entering a valid user code RELATED OPTIONS P90E 5E Enable remote Aux control When this option is on AUX4 is turned ON or PULSED with the telephone keypress 44 AUX4 is turned OFF with the telephone keypress 44 Feedback tones heard by phone 3 beeps The AUX has been turned ON or is already ON 1 beep The AUX has been turned OFF or is already OFF 1 long bee...

Page 66: ...ggles the option ON and OFF OFF Option disabled ON AUX5 telephone remote control enabled P151E 7E Reader Output to AUX5 Program Mode level Installer mode or NessComms Factory Default OFF RELATED OPTIONS P318E P328E P338E P319E P329E P339E This option enables an access control reader to pulse AUX5 when a valid access card is presented Set the reader using P318E P328E or P338E Programming sequence P...

Page 67: ...in D8x D16x V8 and later Program Mode level Installer mode or NessComms V5 3 or later Factory Default Level 99 highest Sets the Audible Alarm volume level for the Siren output Select volume from 1 lowest to 99 highest To Program Press P160E The existing volume level will be displayed Press NEW LEVEL E The new level will be displayed P161E Fire Siren Volume Available in D8x D16x V8 and later Progra...

Page 68: ...1E enables double key PANIC 2E enables double key FIRE 3E enables double key MEDICAL on KPX Saturn Enables MEDICAL on Navigator 4E enables Entry Chime in Day mode Used to announce entry in Day mode 5E enable Chime in Home Mode Used to announce entry in Home mode 8E disable One Digit At A Time Display This allows Navigator keypads to immediately display numeric options P129E End Of Line Resistor Op...

Page 69: ...he user code for use by AutoTime Programming Steps Programming Steps HOME ARMED ARMED Arm or Disarm automatically at pre programmed times of day or day of the week This feature can save a site manager many headaches and hours of travel time There is no need to rely on staff remembering to arm or disarm the system Turn outputs on or off at pre programmed times every day once a week anytime Automate...

Page 70: ... 5 minutes Notes This option sets the warning period for all AutoTimers Related Options P353E 6E AutoTimer1 keypad beeps P358E 6E AutoTimer2 keypad beeps P363E 6E AutoTimer3 keypad beeps P368E 6E AutoTimer4 keypad beeps P373E 6E AutoTimer5 keypad beeps P378E 6E AutoTimer6 keypad beeps P383E 6E AutoTimer7 keypad beeps P388E 6E AutoTimer8 keypad beeps This option enables a keypad beep to warn that a...

Page 71: ...r Codes enabled for AutoTime are disabled at the time set above To Enable pre event Warning beeps 6E Keypad Beeps Turn this option on to enable the AutoTimer Warning continuous slow beeps The keypad s will beep to warn that this AutoTimer is about to begin Keypad beeps begin xx minutes before the AutoTimer is due to start as set by option P390E 1 To silence the beeps during the warning period Pres...

Page 72: ...V RED J2 RECEIVER DATA WHITE RSSI BLUE OV BLACK Ness Radio Interface Part No 100 200 Ness D8x d16 Control Panel Notes The Ness Radio Interface should be installed outside the control panel to prevent interference from the control panel s electronics If the Radio Interface must be installed inside a metal enclosure the antenna wire should protrude outside the enclosure In cases where radio receptio...

Page 73: ... next to the switch A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first D If SUPERVISED SIGNALS have also bee...

Page 74: ...ogrammed the READY light will not turn on and a warning beep will sound To clear the code press 0E then go back to step 5 0E clears any existing codes Press the OFF button on the Radio Key to be programmed If the Radio Key is accepted the READY light will turn off and 3 beeps will sound If the READY light stays on and a warning beep sounds the Radio Key is already assigned to another User Code and...

Page 75: ...controllers dataloggers and other Messages are in ASCII format Due to space constraints the full protocol is not printed in this manual but is available on request Programming sequence P199E 1E 5E toggles the option ON and OFF 1E ON Send Address The address is the last digit of Acc No 2 P73E 2E ON Send Time Stamp 3E ON Send Alarms 4E ON Send Warnings 5E ON Send Access Events 6E ON Send Zone Seal S...

Page 76: ...EADY light will turn off and 3 beeps will sound If the READY light stays on and a warning beep sounds the access card is already assigned to another user code and must be cleared from that user code first Once a card is programmed to a user code it can be used to Arm the panel To allow arming with a double read enable option P301E 2E To allow arming with a single read and pushbutton enable option ...

Page 77: ... zone DisArm with Access Card When this option is enabled a valid access card will disarm the panel It will perform the same function as a keypad code E or a radio key off button Programming sequence P301E 4E toggles the option ON and OFF OFF Do not Disarm with access card ON Disarm with access card P301E 4E Program Mode level Installer mode or NessComms Factory Default ON Request To Exit REX inpu...

Page 78: ... 11 12 13 14 15 16 P303E DoTL zones Dotl Time Sets the delay time in seconds before a DOTL zone generates a DOTL alert Enter a value between 01 and 99 Programming sequence P304E existing DOTL time is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time P304E Program Mode level Installer mode or NessComms Factory Default 20 seconds Option No Description Default...

Page 79: ...mer to hours to give the option for extra long DOTL times 4E OFF DOTL Timer in seconds or minutes as set by P305E 3E Factory default 4E ON DOTL Timer in hours DOTL Alerts to Output Expander With this option on DOTL alerts will be sent to the optional Output Expander on the same output number as the DOTL zone number P305E 1E settings apply 2E OFF No DOTL Alerts to the Output Expander Factory defaul...

Page 80: ... to Aux1 P121E 8E must also be on 2E ON Reader 3 output to Aux2 P122E 8E must also be on 3E ON Reader 3 output to Aux3 P123E 8E must also be on P318E 1E 8E Related options P121E 8E P122E 8E P123E 8E P124E 8E P151E 7E P152E 7E P153E 7E P154E 7E P319E P329E P339E P328E 1E 8E Related options P121E 8E P122E 8E P123E 8E P124E 8E P151E 7E P152E 7E P153E 7E P154E 7E P319E P329E P339E program mode level I...

Page 81: ... 1 24 seconds Programming sequence P319E P329E or P339E existing Reader Output Time is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time 4E ON Reader 3 output to Aux4 P124E 8E must also be on 5E ON Reader 3 output to Aux5 P151E 7E must also be on 6E ON Reader 3 output to Aux6 P152E 7E must also be on 7E ON Reader 3 output to Aux7 P153E 7E must also be on 8E...

Page 82: ...nd For cable runs exceeding 75m use the Ness Weigand data repeater Request To Exit REX using a keypad code Codes selected for Code Only Arming can be used as REX codes for access control functions That is the code can operate an output instead of arming disarming the panel There are two conditions needed to make the code operate as a REX code It is assigned to CODE ONLY ARM and it is not assigned ...

Page 83: ...en acknowledged End of messages To control the security system press 2 then after the tone press 2 again To acknowledge and end press STAR then press HASH and then hang up the phone Press STAR then HASH to hang up Press 2 then 2 to continue to the telephone remote control menu See page 85 This section applies to V8 0 and later Audible Monitoring Note that the operation of Audible Monitoring has ch...

Page 84: ...selected auxiliary output 1 to 8 Then press STAR to activate or HASH to turn off the selected output Press STAR to return AUX 1 ON Auxiliary 1 ON AUX 2 ON Auxiliary 2 ON AUX 3 ON Auxiliary 3 ON AUX 4 ON Auxiliary 4 ON AUX 5 ON Auxiliary 5 ON AUX 6 ON Auxiliary 6 ON AUX 7 ON Auxiliary 7 ON AUX 8 ON Auxiliary 8 ON AUX 1 OFF Auxiliary 1 OFF AUX 2 OFF Auxiliary 2 OFF AUX 3 OFF Auxiliary 3 OFF AUX 4 OF...

Page 85: ...or disarm the security system press 1 To control OUTPUTS press 2 To exclude or include a zone press 3 To listen to reports press 4 To hang up press STAR then press HASH The user presses 2 to control outputs and the voice prompt continues with the message Double press the selected auxiliary output 1 to 8 Then press STAR to activate or HASH to turn off the selected output Press STAR to return The us...

Page 86: ... 12 P212E ON 13 P213E ON 14 P214E ON 15 P215E ON 16 P216E ON 17 P217E ON 18 P218E ON 19 P219E ON 20 P220E ON 21 P221E ON 22 P222E ON 23 P223E ON 24 P224E ON 25 P225E ON 26 P226E ON 27 P227E ON 28 P228E ON 29 P229E ON 30 P230E ON 31 P231E ON 32 P232E ON 33 P233E ON 34 P234E ON 35 P235E ON 36 P236E ON 37 P237E ON 38 P238E ON 39 P239E ON 40 P240E ON 41 P241E ON 42 P242E ON 43 P243E ON 44 P244E ON 45 ...

Page 87: ...larm OFF 7E Exit BEEPS Full Arm off 8E Exit BEEPS Home Mode off Option Description Default Page P00E Follow Me Telephone Number none 38 P26E Entry Delay Time 1 20 sec 16 P27E Entry Delay Time 2 6 60 sec P28E Exit Delay Time 60 sec P29E Siren Reset Time 5 min P30E Normal Zone Sensitivity all zones 17 P31E 36E Vibration Sensitivity High Low none P37E Long Response Zones 1 second none P38E Long Respo...

Page 88: ... level connecting to modem OFF D8x D16x V8 Programming Options Summary Page 3 of 6 Option Description Default Page P88E 1E Send AREA 1 Open Close reports OFF 46 47 2E Send AREA 2 Open Close reports OFF 3E Siren Chirp on Kiss off OFF 4E Flash Strobe on Kiss off OFF 5E Forced Opening report ON 6E Delayed Closing Reports OFF 7E Manual Exclude Reports ON 8E Auto Exclude Reports ON P89E 1E Enable Test ...

Page 89: ...1E Area 1 Armed to AUX1 OFF 59 2E Area 2 Armed to AUX1 OFF 3E Home Armed to AUX1 OFF 4E Keypad toggle AUX1 OFF 5E Telephone remote control of AUX1 OFF 6E not used OFF 7E not used OFF 8E Pulse AUX1 OFF Option Description Default Page P142E 1E Area 1 Armed to AUX2 OFF 61 2E Area 2 Armed to AUX2 OFF 3E Home Armed to AUX2 OFF 4E Keypad toggle AUX2 OFF 5E Telephone remote control of AUX2 OFF 6E not use...

Page 90: ...1E DOTL output LATCHES OFF 2E DOTL outputs to Output Expander OFF 3E DOTL Timer in Minutes OFF 4E DOTL Timer in Hours OFF 5E DOTL zone flashes on keypad OFF D8x D16x V8 Programming Options Summary Page 5 of 6 Option Description Default Page Aux Outputs P318E 1E Ultraprox Reader 1 to AUX1 OFF 80 2E Ultraprox Reader 1 to AUX2 OFF 3E Ultraprox Reader 1 to AUX3 OFF 4E Ultraprox Reader 1 to AUX4 OFF 5E...

Page 91: ...4E 1E AREA 1 disarm 2E AREA 2 disarm 3E HOME disarm 4E Uses AUX7 8 not AUX3 4 5E AUX3 TOGGLE 6E AUX3 PULSE 7E AUX4 TOGGLE 8E AUX4 PULSE AutoTimer 6 P375E Minutes 0 59 P376E Hours 0 23 P377E Days 1 Sunday P378E 1E AREA 1 arm 2E AREA 2 arm 3E HOME arm 4E Code Enable 5E Code Disable 6E KEYPAD Beeps 7E RESET O P Beeps 8E Extend AutoTIME P379E 1E AREA 1 disarm 2E AREA 2 disarm 3E HOME disarm 4E Uses AU...

Page 92: ...m horn speakers Strobe 12V DC timed output Maximum 2 x 1 Watt strobe lights Reset 12V DC timed output Maximum 3 x 12V piezo screamers Equipment power output 13 8V DC output for powering detectors and other equipment Maximum 500mA Control panel Packing List 1 D8XD or D16XD Main board 1 Housing 1 Keypad not supplied with all models 1 Power supply Australia only 1 12V 7Ah battery optional 1 Dialler t...

Page 93: ...ng Aux2 did not timeout after 2sec but followed zone state Fixed Real Time Clock speed up Hardware change V7 5 September 2011 Fixed fire siren turnoff It was changing to standard siren instead of switching off Allow NAVIGATOR v2 keypads to display time stamped event memory Up to 80 events are displayed with TIME DATE and EVENT ZONE NAMES and USER NAMES are also displayed The NAVIGATOR allows the u...

Page 94: ...NOTES ...

Page 95: ...ER CODE USER CODE USER CODE OPTION No OPTION No OPTION No Extra Options Assigned E g Radio Code Arm Only etc Extra Options Assigned E g Radio Code Arm Only etc Extra Options Assigned E g Radio Code Arm Only etc 1 20 39 P201E P220E P239E Master Code 2 21 40 P202E P221E P240E 3 22 41 P203E P222E P241E 4 23 42 P204E P223E P242E 5 24 43 P205E P224E P243E 6 25 44 P206E P225E P244E 7 26 45 P207E P226E P...

Page 96: ......