background image

InstallatIon

3

J1

RECEIVER

LISTEN

SERIAL

READER

PROG

T

AMP

BA

T

TERY

RED +

TELEPHONE

HEATSINK

AUX1

AUX2
AUX3
AUX4

+12V

0V

TAMP

+12V

+12V

+12V

0V

Z8

C

Z7

Z6

C

Z5

Z4

C

Z2

Z3

C

Z1

0V

CLK

DAT

COM

K

E

Y

P

A

D

RESET

STR

SIREN

17V

AC

AC

EARTH

BLACK

BOX TAMPER
SWITCH
N.C. Contacts
(WHITE)

J1 LINK

&

BOX TAMPER

PROGRAM LINK

= Sealed, normal state
= Tamper alarm state

Power up with link off to enter
installer program mode

BATTERY LEADS
(supplied)

“HEARTBEAT” LED

Constantly flashes

D8X MAIN BOARD

LISTEN PINS

Diagnostics. Connect an
8 Ohm horn speaker to
listen to dialler tones.

BATTERY CONNECTION

For 12V 7Ah backup
battery (BAT210)

RECEIVER

Header for
connecting
optional Radio
Interface.

AUX

Aux outputs
1-4.

SERIAL

Connection for
direct up/download
using NessComms
software

READER

Connection for
up to 3 Ness
Weigand readers

D8x / D16x main Board

Blue
White
Black

Red

DAT
CLK
COM
+12V

Saturn Keypad rear

4 pin header.

Crimp connectors
(Supplied)

Wiring

Keypad should be wired to the control panel using minimum 7/020 security cable.

Up to three Saturn keypads can be connected per control panel as long as the 
maximum current draw for all detectors and keypads is below 500mA.
Maximum allowable cable distance is 100m including cable to all keypads. 
Wire additional keypads in “star” configuration to the control panel.

Summary of Contents for 106-108-WHT Saturn Keypad White

Page 1: ...ber 890 405 Rev 1 Architecturally designed premium keypad Glossy glass look fascia High Contrast LCD icon display White and Red LCD backlighting Red LCD backlighting for alarm memory Satin finish tactile buttons Laser etched graphics Adjustable keypad beep volume Adjustable LCD brightness Adjustable blue keypad backlighting Supports D8x D16x V6 panels Image Saturn keypad White ...

Page 2: ... lock the bottom lugs Accessories supplied 1 x 4 wire loom 2 x Low profile self tapping screws 2 x Low profile machine screws 4 x Gel crimp connectors Important Note To achieve an extremely low profile this premium keypad is designed with close internal tolerances Use only the Low Profile screws provided Larger screw heads may damage the circuit board and invalidate your warranty Cable entry Reces...

Page 3: ...N PINS Diagnostics Connect an 8 Ohm horn speaker to listen to dialler tones oad ms s D8x D16x Main Board Blue White Black Red DAT CLK COM 12V Saturn Keypad REAR 4 pin header Crimp connectors Supplied Wiring Keypad should be wired to the control panel using minimum 7 020 security cable Up to three Saturn keypads can be connected per control panel as long as the maximum current draw for all detector...

Page 4: ...elease when the desired volume is reached A short beep will be heard at the highest level 10 Levels 10 Levels Adjustable red LCD backlighting for Alarm Memory Adjustable blue keypad backlighting Adjustable keypad beep volume Key pairs for Panic Fire Medical alarms Satin finish buttons with tactile click Adjustable White LCD back lighting Low installation profile Stylish and elegant glass look fasc...

Page 5: ...splayed on the LCD during adjustment Red backlight Saturn Keypad has a unique high visibility flashing RED backlight mode which is triggered by any alarm event The red backlighting is designed to be especially visible to alert you that an alarm event has occurred and is present in the alarm memory Red backlight options The flashing red backlight option has three methods of operation selectable by ...

Page 6: ...rate AUX3 press 33 to turn on press 33 to turn off To operate AUX4 press 44 to turn on press 44 to turn off Special Key Functions These Double Key functions are only available when the Saturn keypad is used with D8x D16x panels V6 and later Not applicable to previous panel versions Panic Alarm Press the 1 3 keys together for FIRE alarm Press and hold the keys for at least 1 5sec Fire Alarm Press t...

Page 7: ...d has keypad pairs for Panic Fire and Medical alarms and special chime modes These program options are available only in D8x D16x V6 and later To Program 1 Press P126E 2 Press 1E 5E to turn an option ON or OFF 1E ON enables double key PANIC 2E ON enables double key FIRE 3E ON enables double key MEDICAL 4E ON enables Entry Chime in Day mode Used to announce entry in Day mode 5E ON enable Chime in S...

Page 8: ...served No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement...

Reviews: