24
Repair
Service Manual EF 347 / EF 348
en
Version 1.0
Replacing pump
Tools:
- Torx screwdriver Pin-TX10
- Long-nose pliers
- Blade screwdriver, no. 7
Procedure:
1. Follow general disassembly (see page
21).
2. Remove clip (14) and O-ring (15).
3. Remove pump (17).
4. Remove electrical connections from
pump.
5. Replace defective pump (17).
6. Plug in electrical connections on pump.
Check for correct wiring of pump.
7. Insert new O-ring (15).
8. Mount angled hose (26) with clip (14).
14
17
26
T 128°C
L
15