If the induction cooker
operates for two hours and no
key is pressed in working
mode, it will go to standby
mode automatically (except
that timing period exceeds two
hours).
1-Minute Auto Shutdown
Protection:
If the pot is moved away, the
induction cooker will stop
heating immediately. After the
buzzer sound about 1 minute,
it will go into standby mode
automatically.
Failure and Protection Code:
If an abnormally comes up, the
induction cooker will enter
protective mode automatically
and display corresponding
protective codes.
Failure
Main PCB at Fault
Top plate over heat
Code
E7
E8
Failure
Utensil not placed
Supply voltage too high
transducer of the heat
sink
Supply voltage too low
Bottom of the pot over
heated
Heat sensor open circuit
or short circuit
Over current protection
Code
E1
E2
E3
E4
E5
E6
11
Applicable Pots:
- Please use the pots sold along
with the unit by recommended.
- It is better not to use other ,
alternatives so as to avoid any
unfavorable influence on the
operational performance.
- If using other pots, please
observe the following
conditions:
*Requirement for pot materials:
containing magnetic inducting
materials.
*Shape requirement: flat bottom,
the diameter within the range of
12cm. and 22cm.
- During operating, you may hear
high-frequency electro-
magnetic noise, which is caused
Summary of Contents for Solarist NC 501