Problem

Problem Cause

Remedy

When switched On 

the machine will not 

start working

Plug is not well connected or

electric socket is faulty.

Thermal safety switch has

tripped due to overheating.

The nozzle is on the high

pressure step.

Seal worn out.

Safety catch on.

The machine can not

suck soap

Water leaking from

the pump

Lance trigger will

not operate

Water inlet filter I clogged.

Safety valve spring loosen.

Cheek valve or plunger or 

seal broken.

Pump  sucking  air f rom

connections  or  hoses.

Check that all supply connections 

are tight.

Valves dirty, worn out or

stuck.

Pump seals worn out.

Pump sucking air.

Lance nozzle incorrect or

worn out.

The motor stops

suddenly

Fluctuating pressure

The pump does not 

reach the necessary 

pressure

Trigger in off mode.

Check plug, socket and fuses.

Check that the main voltage

corresponds to specifications.

Follow the 15 instructions to

adjust.

Check or Contact dealer for

check and repaired.

Release safety catch.

Clean the water inlet filter.

Contact dealer for check and

repaired.

Contact dealer for check and

repaired

Check that connections between

hose and faucet, water inlet 

 

 

 

 

enter are tight, check that crack

axist on host.

Check lance nozzle or Contact

dealer for check and repaired.

The trigger.

Check the main voltage is

adequate.

Switch off the unit and let it

cool for a few minutes.

The main voltage is insufficient, 

lower than minimum

requirement.

Trouble Shooting Guide

22

Summary of Contents for NC-59101

Page 1: ...HIGH PRESSURE WASHER MODEL NC 59101 1800 W 220 240 V 50 Hz Instruction Manual...

Page 2: ...1...

Page 3: ...NC 59101 NESCO A B C D E F G H I 1800 220 240 50 2...

Page 4: ...3 1 2 3 4 5 1 2 3 4 5 6 7 1 2 3 84...

Page 5: ...4 4 5 6 7 8 9 10 11 85...

Page 6: ...5 12 13 14 15 16 17 18 1 2...

Page 7: ...6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 13 25...

Page 8: ...17 18 1 2 3 4 5 6 1 70 2 3 4 1 3 2 4 7...

Page 9: ...7 8 9 11 12 10 5 6 7 8 10 9 5 6 7 8 9 10 8...

Page 10: ...1 2 3 2 3 1 11 12 13 14 15 16 17 11 12 1 2 15 3 45 9...

Page 11: ...15 10...

Page 12: ...13 13 1 11...

Page 13: ...12...

Page 14: ...13...

Page 15: ...tisfaction for many years Introduction Carefully read and understand this manual and any label attached to the tool before use Keep these instructions with the product for future reference Ensure all...

Page 16: ...tation and storage Plastic main body looks nice Safe in use Plastic spray lance light and comfortable when use Adjustable nozzle to adjust water into different shapes freely and the pressure a well Eq...

Page 17: ...ce Vibration can cause disease Gloves to keep the operator warm and dry and therefore maintain good blood circulation in the fingers may help This tool has not been designed for extended or industrial...

Page 18: ...owerful and can cause serious injury Avoid aiming the jet at the pressure washer body or the power supply Do not use in an area where ventilation could be limited and NEVER cover the unit while it is...

Page 19: ...ptively heavy so take care when lifting NEVER connect the pressure washer to the hot water supply as this will rapidly reduce the life of the pump It is necessary to turn on the spray lance within one...

Page 20: ...screws see fig 4 Connect the nozzle onto the spray lance and the lance onto the gun handle see fig 5 6 7 Loosen the high pressure hose to avoid twist Connect the gun with the high pressure hose see fi...

Page 21: ...16 17 13 14 15 Connect the water supply hose to the water entry of the machine see fig 10 Connect another end of the supply hose to water source After use turn off the water lap and then the switch F...

Page 22: ...utes switch the pressure washer off Prior to each time of use it is necessary to bleed the trapped air within the lance It is recommended that positioning the lance at a 45 angle to the surface to be...

Page 23: ...ir Lance nozzle incorrect or worn out The motor stops suddenly Fluctuating pressure The pump does not reach the necessary pressure Trigger in off mode Check plug socket and fuses Check that the main v...

Page 24: ...prior notice Company reserved the right to change all details before notice MAINTENANCE CLEANING When It is highly recommended that you clean the nozzle with the cleaning pin see fig 13 after each use...

Page 25: ...www nescoproduct com...

Page 26: ......

Reviews: