.1. Change of operation mode, command time and auto closing time
Action
Indication
1. Input the device in programming mode of operation modes
1) i
nput in the PM of remote controls: press and hold the
programming button for more than 4 sec.;
2) i
nput in PM of operation modes: press and hold the
programming button for more than 1 sec. (up to yellow
flash).
1) v
isual indicator blinks
red;
2) v
isual indicator blinks
green for certain times.
2. Change the device operation mode
The modes are switched circle-wise each time you press
and hold the programming button for more than 1 sec. (up
to yellow flash).
Number of flashes:
1- s
hort command mode;
2- r
oller shutter mode
(factory setting);
3- r
oller shutter mode with
auto closing;
4- c
ontinuous command
mode.
3. Change the command time (in the PM of operation mode)
The time setting is carried out only using connected key switch without the
fixation of pressed position.
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) to set the 2
nd
operation mode;
3) to install the roller shutter in the lowermost position by
pressing the “DOWN” button;
4) to start the time countdown by pressing shortly the “UP”
button;
5) to wait for 3-5 sec. and press the “DOWN” button when
the roller shutter is stopped in uppermost position. New
time will be recorded in the device memory.
The visual indication of the
second operation mode –
double green flashes.
4. Change the time of auto closing timer (in the PM of operation mode)
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) to set the 3rd operation mode;
3) to start the time countdown by pressing shortly the “UP”
button;
4) to press the “DOWN” button when the necessary time is
expired. New time will be recorded in the device memory.
The visual indication of the
third operation mode –
triple green flashes.
5. Reset to the factory setting (in the PM of operation mode)
1)
to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) p
ress and hold the programming button for more than 4
sec.
The visual indicator will
flash yellow after 1 and 4
sec., and then it will
continue to blink double
green light.
6. Output the device from the programming mode
Press twice shortly the programming button.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
7
. Safety inputs
7
.1. Connection of safety devices
The device can operate with the following safety devices:
- reed switch (fig. 4);
- optical sensors SIGNAL12 (fig. 5);
- infrared barrier with NO and NC contacts (fig. 6);
- device for group opening of roller shutters with NO and NC contacts (clause 6.2).
When the device is blocked by the sensor, the red visual indicator will flash continuously. The
device will be unavailable to control. In this situation, it is necessary to eliminate the obstacle
in the operation area of the sensor or to change the operation mode in accordance with the
connected sensor.
The device has 5 operation modes of safety inputs (PM of safety inputs) for the organization
of work with the safety elements.
Modes 1-4 determine the contact type of the infrared barrier (reed switch) and the response of
the device when sensors are blocked during the movement:
1. NO-sensor: when the device is closed, it will execute the “STOP” command.
2. NO-sensor (
factory setting
): when the device is closed, it will execute the “STOP”
and “UP” commands.
3. NC-sensor: when the device is opened, it will execute the “STOP” command.
4. NC-sensor: when the device is opened, it will execute the “STOP” and “UP”
commands.
When the IS15 insertion is deformed, the optical beam of the optical sensors SIGNAL12 is
interrupted, and the device always executes the “STOP” and “UP” commands. The response
does not depend on the selected mode (1-4). The “UP” command is executed only when the
sensor is blocked during the “DOWN” movement.
The fifth mode allows you to control groups of devices Radio 8113 IР65 through one dry
contact by applying / dumping power 12 V (cl. 6.2).