background image

7

.2. Group control of devices

You can use NO or NC contact type to control the devices. 
A jumper between the contacts 13-15 allows you to invert the effect of the device on the roller 
shutter. 
Device Radio 8113 IР65 or another power supply can serve as a 12 V power supply. 

For example, if you use the NC-contact, then this connection scheme will support the 
monitoring of control line integrity. When a wire breaks, all roller shutters will raise/lower as 
if the control contact is opened. It is necessary to set the 5th operation mode of the safety inputs 
to implement this functionality (cl. 6.3). 

Inadvertent  activation  is  possible  with  a  large  length  of  the  control  line  and 
significant settings to it. Division of the control line into two with coupling of 12 
V intermediate relay can serve as the solution of a problem. You should use  the 
power supply from different devices Radio 8113 IP65 for each line. 

7

.2.1. Control of group of devices, a jumper is not installed (fig. 7)

- when the contact is closed, the device will execute the “DOWN” command, the control from
the remote controls and key switch will be blocked;
- when the contact is opened, the device will execute the “UP” command, the control from the
remote controls and key switch will be available;
- after  power  re-supplying  when  the  contact  is  opened,  the  device  will  execute  the  “UP”
command;
- after power re-supplying when the contact is closed, the device will execute the “DOWN”
command.

7

.2.2. Control of group of devices, a jumper 13-15 is installed

- when the contact is closed, the device will execute the “UP” command, the control from the
remote controls and key switch will be available;
- when the contact is opened, the device will execute the “DOWN” command, the control from
the remote controls and key switch will be blocked;
- after power re-supplying when the contact is opened, the device will execute the “DOWN”
command;
- after  power  re-supplying  when  the  contact  is  closed,  the  device  will  execute  the  “UP”
command.

Fig. 6 Connection of infrared barrier 

Fig. 5 Connection of optical sensor SIGNAL12 

Fig. 4 Connection of reed switch 

Fig. 7 Variant of control without a jumper 

Fig. 8 Variant of control with a jumper 

+12 V 

brown

;

output 

-

  green

;

general - white

12 V

12 V

Summary of Contents for Radio 8113 IР65

Page 1: ...and to the electric drive It is prohibited to use mounting wires and cables with polyethylene insulation or sheath It is prohibited to install the device at a distance less than 1 m from heating devices The holes in feedthrough plate should be punctured using a tool of smaller diameter than the input cable It is prohibited to supply 220 230 V voltage to the terminals 8 15 To consider 220 V as the ...

Page 2: ...y of the device PM of remote controls Press and hold the programming button for more than 4 sec The visual indicator will flash red for a long time twice 5 Output the device from the PM of remote controls Press short the programming button The visual indication stops The device is automatically removed from the programming mode if no actions are performed with it during 32 sec 6 Operation modes Th...

Page 3: ...epeatedly the device in the PM of operation mode if it is necessary 2 press and hold the programming button for more than 4 sec The visual indicator will flash yellow after 1 and 4 sec and then it will continue to blink double green light 6 Output the device from the programming mode Press twice shortly the programming button The visual indication stops The device is automatically removed from the...

Page 4: ...d the device will execute the DOWN command the control from the remote controls and key switch will be blocked when the contact is opened the device will execute the UP command the control from the remote controls and key switch will be available after power re supplying when the contact is opened the device will execute the UP command after power re supplying when the contact is closed the device...

Page 5: ...ec Retransmission of remote control marking is carried out only together with the control of power relay 8 1 Turning on off the retransmission function Action Indication 1 Input the device in programming mode of repeater from the standby mode Press and hold the programming button for more than 8 sec Visual indicator blinks green for certain times 2 Change the operation mode of repeater Turning on ...

Page 6: ... or green but the voltage is not supplied on drive a the jumper between terminals 6 and 7 is not installed b the jumper between terminals 6 and 7 is not clamped well a install the jumper between terminals 6 and 7 b clamp the jumper between terminals 6 and 7 The device is not entered in the programming mode a latching switch is connected and the button of one of directions is pressed a change the l...