background image

 

12 

www.nerival.fi

 

Settings 

Press the 

 button to enter the setting mode.  

Use the 

 and 

 buttons to select the setting you want to set.  

Press the   decrease or   increase button to set the desired value. 
To save the setting and exit the setting mode, press the 

button. 

General settings 1-22 

Setting 

number 

Function 

Setting 

range 

Factory 

setting 

Additional information 

Opening speed 

0-30 

25 

The higher the value, the faster the 

door opens 

Closing speed 

0-30 

20 

The higher the value, the faster the 

door closes 

Opening angle 

0-99 

45 

The higher the value, the larger the 

opening angle 

Door hold open time 

0-30 

0-30 seconds opening time after the 

door has opened 

Slow opening angle 

0-30 

The higher the value, the greater the 

angle at which the door opens slowly 

Slow closing angle 

0-30 

The higher the value, the greater the 

angle at which the door closes slowly 

Closing force 

0-10 

The higher the value, the greater the 

closing force 

Type of electric lock 

0-3 

0: magnetic lock 

1: electric lock 

2: fail safe electric strike 

3: fail secure electric strike 

Opening direction 

0-1 

0: left 

1: right 

10 

Adding a remote 

control 

0-40 

see Adding a remote control 

Additional controller e.g.  

Nerival #33340 RCT-1224

 

11 

Opening door anti-

collision delay 

0-10 

The lower the delay, the faster the 

door stops in a collision 

12 

Closing door anti-

collision delay 

0-10 

The smaller the delay, the faster the 

door opens in a collision 

13 

Closing speed after 

reset 

0-10 

Closing speed after reset 

14 

Low speed 

0-10 

Minimum deceleration speed 

15 

Unlock delay

 

0-0 

The lock is released first, after which 

the door opens after a set delay of 0 

seconds 

16 

Push / pull to open 

0-1 

0: off 

1: on 

17 

Remote control mode 

0-1 

0: Buttons have different functions 

1: All buttons open the door 

18 

Force to keep open 

0-10 

0: minimum 

10: maximum 

Summary of Contents for NEO-80

Page 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 80...

Page 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Connection 9 Button functions 11 Settings 12 Gen...

Page 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Page 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Page 5: ...justable Opening angle 0 99 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 20 55 Protection class IP12D Dimensions 5...

Page 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Page 7: ...fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door Adjust the limit block in the correct position when the...

Page 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Page 9: ...Double door synchronization Synchronization of two door operators COM COM Sensor power supply Sensor output 12VDC Sensor power supply Sensor output 12VDC Sensor signal Sensor signal input Sensor signa...

Page 10: ...he input is active the display shows F3 Access control signal COM Signal opens the door from access control The input is either a voltage signal of 12VDC or a short circuit signal When the input is ac...

Page 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Page 12: ...greater the angle at which the door closes slowly 7 Closing force 0 10 8 The higher the value the greater the closing force 8 Type of electric lock 0 3 0 0 magnetic lock 1 electric lock 2 fail safe e...

Page 13: ...value the slower the minimum speed 24 Damping compensation 0 4 1 The higher the value the higher the damping force 25 Deceleration ramp 0 5 2 The higher the value the greater the slope 26 Opening angl...

Page 14: ...rol Adding a remote control 1 Go to setting no 10 and press the parameter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remo...

Page 15: ...ls disabled Error code Cause Solution E0 System error Replace the controller E1 The motor is not connected Check motor connection E2 Motor line failure Check motor connection replace the motor E3 No m...

Reviews: