background image

 

www.nerival.fi

 

Technical information 

Model 

NEO-80 

Door max. weight 

100kg, recommended  80kg 

Door max. width 

1200mm, recommended 1000mm 

Weight 

6,5kg 

Service life 

More than 1.000.000 operations 

Installation method 

Surface mounting 

Voltage output for locking 

12VDC 

With included relay card  

12V AC/DC - 30V AC/DC  

Door hold-open time 

0-30s, adjustable 

Opening angle 

0°-99°, adjustable 

Supply voltage 

230VAC 

Max. power 

45W 

Standby power consumption 

< 2W 

Remote control distance 

Over 30m 

Operating temperature 

-20

 - 55

 

Protection class 

IP12D 

Dimensions 

515mm x 95mm x 90mm 

 

Approvals 

 

 

EU Directive 

Test Standard(s) 

2011/65/EU 

(RoHs) 

EN 62321-1:2013 
EN 62321-2:2014 
EN 62321-3-1:2014 
EN 62321-4:2014+A1:2017 
EN 62321-5:2014 
EN 62321-6:2015 
EN 62321-7-1:2015 
EN 62321-7-2:2017 
EN 62321-8:2017 

EU Directive 

Test Standard(s) 

2014/30/EU 

(EMC) 

EN IEC 61000-6-1:2019 
EN 61000-6-3:2007/A1:2011 
/AC:2012 

Summary of Contents for NEO-80

Page 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 80...

Page 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Connection 9 Button functions 11 Settings 12 Gen...

Page 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Page 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Page 5: ...justable Opening angle 0 99 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 20 55 Protection class IP12D Dimensions 5...

Page 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Page 7: ...fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door Adjust the limit block in the correct position when the...

Page 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Page 9: ...Double door synchronization Synchronization of two door operators COM COM Sensor power supply Sensor output 12VDC Sensor power supply Sensor output 12VDC Sensor signal Sensor signal input Sensor signa...

Page 10: ...he input is active the display shows F3 Access control signal COM Signal opens the door from access control The input is either a voltage signal of 12VDC or a short circuit signal When the input is ac...

Page 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Page 12: ...greater the angle at which the door closes slowly 7 Closing force 0 10 8 The higher the value the greater the closing force 8 Type of electric lock 0 3 0 0 magnetic lock 1 electric lock 2 fail safe e...

Page 13: ...value the slower the minimum speed 24 Damping compensation 0 4 1 The higher the value the higher the damping force 25 Deceleration ramp 0 5 2 The higher the value the greater the slope 26 Opening angl...

Page 14: ...rol Adding a remote control 1 Go to setting no 10 and press the parameter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remo...

Page 15: ...ls disabled Error code Cause Solution E0 System error Replace the controller E1 The motor is not connected Check motor connection E2 Motor line failure Check motor connection replace the motor E3 No m...