7. Wiring
Colour
Function
Description
Pink
BELL_A
Doorbell button one end, max. 3A
Pale blue
BELL_B
Doorbell button to the other end, max. 3A
Green
D0
WG output D0
White
D1
WG output D1
Grey
ALARM
Alarm negative(alarm positive connected 12-24 V+)
Yellow
OPEN
Exit button one end(the other end connected GND)
Brown
D_IN
Magnetic switch one end(the other end connected GND)
Red
12-24V+
12-24V + DC Regulated Power Input
Black
GND
12-24V - DC Regulated Power Input
Blue
NO
Relay normally-on end(Connect positive electric lock "-")
Purple
COM
Relay Public end, connect GND
Orange
NC
Relay Closed end(connect negative electric lock "-")
Common power supply diagram:
:
Bell_A
Bell_B
Pink
Pink
D0
D1
Green
White
ALARM
OPEN
Gray
Yellow
D_IN
+12/24V
Brown
Red
Black
Blue
Purple
Orange
GND
NO
COM
NC
Bell
Alarm
Exit button
Door contact
Power supply
12-24VDC
- Power on the lock keep unl
- Power on the lock keep unl
Nerival Oy