9. CONFIGURATION
Figure 14: Screenshot of conguration page for processing settings.
9.3 Processing Settings
9.3.1 Operation Mode
The major processing parameters can be changed on the `processing settings'
page, which is shown in Figure 14. The most relevant option is the operation
mode, which can be set to one of the following values:
Pass through: In this mode SceneScan forwards the imagery of the selected
cameras without modication. This mode is intended for verifying that
both cameras are functioning correctly.
Rectify: In this mode SceneScan transmits the rectied images of both cam-
eras. This mode is intended for verifying the correctness of the image
rectication.
Stereo matching: This is the default mode, in which SceneScan performs the
actual stereo image processing (stereo matching). SceneScan transmits
the rectied image of the left camera and the left camera disparity map.
21