18
Operate under manual function
1.
Press
【↑】
and
【↓】
to adjust the position of X axis
,
Press direction- key correspondingly.
The
X axis will run by speed
the maximum speed limit
the maximum speed limit
the maximum speed limit
the maximum speed limit
* Manual magnification.
Press
【→】
and
【←】
to adjust the position of Y axis. Press direction-key correspondingly,
The Y axis will
run by speed
the maximum speed limit
the maximum speed limit
the maximum speed limit
the maximum speed limit
* Manual magnification.
2
.
Press
【
F1
】
, system will enter into
inch moving
state, Press the direction-key once, Motor will
move one inch increment correspondingly. Press
【
F1
】
again, return to continue state. Press
【
G
】
key can change the inch increment.
3
.
Press
【
F2
】,
system will enter into manual pulse mode, display as follow:
4.
Press
【
F4
】
,system will select
MDI
function
,Under this mode,
You can directly input single
segment program, such as
:
G01 X100 Y200
After input one line, press
【
Enter
】
key to run at once
.
Press
【
Quit
】
key to cancel.
MDI
MDI
MDI
MDI
mode supports various G、M、S instructions.
Note: The MDI instruction inputted will
be saved till modified or power off.
Speed
:
F
×
100%=0000 Program
:
0001 Number
:
0000
X axis
Y axis
1.00
0.10
0.01
0.002
X +00000.000
Y +00000.000
Manual operating
Acetylene closed
Preheat closed
Cutting closed
Cutting tip stop
M05
U 0000.000
V 0000.000
XY coordinate
Enter into manual pulse mode,
Press
【
F1
】
and
【
F2
】
to select
X or Y axis.
Select valid weight:
【
F3
】
- 1.00mm / pulse
【
F4
】
- 0.10mm / pulse
【
F5
】
- 0.01mm / pulse
【 】
www.EngineeringBooksPdf.com