E-Coder)R900
i
Installation and Maintenance Guide
19
7 Data Logging Extraction Steps
The E-Coder)R900
i
stores consumption in hourly intervals for a rolling total of
96 days. This is equal to 2,304 hourly intervals of consumption. A special data
logging activation flashlight is required for this process. This flashlight is used to
activate the E-Coder)R900
i
for data transmission for collection by the CE
handheld unit (HHU). The flashlight must be held within 2-3 inches from the
photo sensor (recessed hole on dial plate) for 3-4 seconds or until the LCD
changes to read “RF Log”. After activation and the data is being received by the
HHU, it takes approximately five minutes to download all 96 days worth of data
logging information.
Extracting Data
Complete the following steps for Data Logging.
1
From the host software home screen on the HHU, click
Menu
. See Figure 8.
Figure 8 HHU Home Screen
2
From the HHU synchronization screen, select
Data Logger
. (See Figure 9
Figure 9 Synchronization Screen
If the User Authentication screen displays, sign in using your Reader ID and
password, if applicable. The HHU starts the initialization of the AMR device
on the HHU at this time.
Summary of Contents for E-Coder)R900i
Page 2: ......
Page 3: ...E Coder R900i Installation and Maintenance Guide ...
Page 6: ......
Page 9: ...Contents E Coder R900i Installation and Maintenance Guide vii Glossary Index ...
Page 10: ...Notes Contents viii E Coder R900i Installation and Maintenance Guide ...
Page 12: ...x E Coder R900i Installation and Maintenance Guide Notes Figures ...
Page 14: ...xii E Coder R900i Installation and Maintenance Guide Notes Tables ...
Page 46: ...Glossary Notes 32 E Coder R900i Installation and Maintenance Guide ...
Page 50: ...36 E Coder R900i Installation and Maintenance Guide Notes Index ...
Page 51: ......