NEP BDM-600 Installation And Operation Manual Download Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: 

ALWAYS DISCONNECT AC POWER BEFORE DISCONNECTING PV MODULE WIRES 

FROM THE BDM-600. THE AC CONNECTOR OF THE FIRST BDM-600 IN A BRANCH CIRCUIT IS 

SUITABLE  AS  A  DISCONNECTING  MEANS  ONCE  THE  AC  BRANCH  CIRCUIT  BREAKER  IN  THE 

LOADCENTER HAS BEEN OPENED. 

 

LED indica

on of error   

 

error mode (except for grounding error) 

The LED light 

fla

shes in 

red

 color. 

 

NOT

 communica

ng with BDG-256, and with no error 

The LED light 

fla

shes in 

orange

 color.   

 

grounding fault 

The LED light is in 

solid red

 color.   

Troubleshoo

ng an inoperable BDM-600   

To troubleshoot an inoperable BDM-600, follow the steps in the order shown:   
1.  Check  the  connec

on  to  the  u

lity  grid.  Verify  that  the  u

lity  voltage  and 

frequency are within allowable ranges shown in the label of BDM-600.   

2. Verify u

lity power is present at the inverter in ques

on by removing AC, then DC 

power.  Never  disconnect  the  DC  wires  while  the  BDM-600  is  producing  power. 

Re-connect the DC module connectors, and then watch for the LED blinks.   

3.  Check  the  AC  branch  circuit  interconnec

on  harness  between  all  the  BDM-600. 

Verify  that  each  inverter  is  energized  by  the  u

lity  grid  as  described  in  the 

previous step.   

4. Make sure that any AC disconnects are func

oning properly and are closed. 

5. Verify the PV module DC voltage is within the allowable range shown in the label 

of BDM-600.   

6. Check the DC connec

ons between the BDM-600 and the PV module. 

7. PLC signal quality may be checked through the interface on the BDG-256 gateway.   

If  the  PLC  signal  is  weak,  it  might  be  due  to  the  distance  between  the  micro 

inverters and the gateway.    It may also be caused by the interference from other 

electronic devices.    In most cases, signal quality may be signi

fican

tly improved by 

moving the BDG-256 to closer to the micro inverter arrays, and/or farther away 

from  other  interferers.    In  some  cases,  a  signal 

lter  (LCF)  may  be  installed  to 

reduce  the  interference  to  PLC  communica

on.    If  there  are  two  or  more 

separate BDM systems close by, it is highly recommended to install LCF for each 

micro inverter system to block interference from adjacent other systems. 

7. If the problem persists, please call customer support at NEP. 

WARNING: 

DO NOT ATTEMPT TO REPAIR THE BDM-600; IT CONTAINS NO 

USER-SERVICEABLE PARTS. IF TROUBLESHOOTING METHODS FAIL, PLEASE RETURN THE 

BDM-600 TO YOUR DISTRIBUTOR FOR MAINTENANCE. 

 

Disconnec

ng a BDM-600 from the PV Module   

To  ensure  the  BDM-600  is  not  disconnected  from  the  PV  modules  under  load, 

adhere to the following disconnec

on steps in the order shown:   

1. Disconnect the AC by opening the branch circuit breaker. 

 

2. Disconnect the

 fi

rst AC connector in the branch circuit.   

3. Cover the module with an opaque cover.   
4. Using a DC current probe, verify  there is no current 

owing in the DC wires 

between the PV module and the BDM-600.   

5.  Care  should  be  taken  when  measuring  DC  currents,  most  clamp-on  meters 

must be zeroed

 fi

rst and tend to dri

� 

with 

me.   

6. Disconnect the PV module DC wire connectors from the BDM-600.   
7. Remove the BDM-600 from the PV array racking.   

Installing a replacement BDM-600 

1.  A

ach  the  replacement  BDM-600  to  the  PV  module  racking  using  hardware 

recommended by your module racking vendor in the same loca

on as the one 

previously removed. 

 
2.  Connect  the  AC  cable  of  the  replacement  BDM-600  and  the  neighboring 

BDM-600s to complete the branch circuit connec

ons.   

3. Obtain serial number of the replacement BDM-600 

 

 

 

 

   

Each BDM-600 has a removable serial number located on the moun

ng plate and 

addi

onal s

ckers in the shipping bag. 

4. Reconnect the PV Modules.   
First connect the posi

ve DC wire from the PV module to the nega

vely marked 

DC  connector  (male  pin)  of  the  BDM-600.  Then  connect  the  nega

ve  DC  wire 

from the PV module to the posi

vely marked DC connector (female socket) of the 

BDM-600. Repeat for the remaining PV modules.     

5.  Replace  the  old  PLC  ID  in  the  BDG-256  gateway  with  the  new  PLC  ID of  the 
newly installed micro inverter. 
 

13

12

Summary of Contents for BDM-600

Page 1: ...433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp Rev 2017 01 12 North American Version Dual Module Microinverter BDM 600 Installa on and Opera on Manual ...

Page 2: ...Shipping Informa on 05 6 INSTALLATION 05 6 1 Pre installa on 05 6 2 Installa on Steps 06 Step 1 System Layout 06 Step 2 Connect the Wiring Harnesses 07 Step 3 Install the AC Branch Circuit Junc on Box 08 Step 4 Ground the System 08 Step 5 Complete the Connec on Map 09 Step 6 Connect the PV Modules 09 Step 7 Install the BDG 256 Monitoring Gateway 09 7 COMMISSIONING 10 8 OPERATING INSTRUCTIONS 10 9 ...

Page 3: ...ds of power electronics automa c control signal processing and communica ons each holding mul ple U S and world patents in their specialty areas NEP has a complete product line of grid ed solar inverters including 180W 600W micro inverters 1 5kW 5kW single phase solar inverters 10kW 500kW three phase solar inverters and rapid shutdown devices Field deployment results demonstrated high system efficie...

Page 4: ...THIS MANUAL IS NOT COVERED BY THE WARRANTEE INSTALLATIONS SHOULD BE DONE ONLY BY CERTIFIED ELECTRICIANS NOTHING INSIDE THE INVERTER SHOULD BE MODIFIED ONLY NEP APPROVED CABLING SHOULD BE USED TO CONNECT MICROINVERTERS ALL INSTALLATIONS SHOULD FOLLOW THE LOCAL ELECTRICAL CODES ADDITIONAL PROTECTION FOR THE AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND NATIONAL WIR...

Page 5: ...rail or frame a ach clamps 2 per microinverter AC junc on boxes mul ple op ons possible Cordgrip with locknut or strain relief fi ng one per branch circuit A subpanel may be required for systems with mul ple branch circuits Cable clips Sockets wrenches torque wrench mul meter small flat head screwdriver and mirror with extension rod Lightning and surge suppressor recommended 5 3 Lightning and Surge ...

Page 6: ...NSTALLED ON ALL UNUSED AC CONNECTORS UNUSED AC BDM 600 WIRE HARNESS CONNECTORS ARE LIVE WHEN THE SYSTEM IS ENERGIZED BY T The AC branch circuit should look as pictured below 6 2 Installa on Steps WARNING CONNECT BDM 600S TO THE ELECTRICAL UTILITY GRID ONLY AFTER RECEIVING PRIOR APPROVAL FROM THE UTILITY COMPANYAND LOCAL AHJ WARNING BE AWARE THAT ONLY QUALIFIED PERSONNEL CAN CONNECT BDM 600 TO THE ...

Page 7: ...ou create Step 6 Connect the PV Modules Connect all AC all system inter wiring connec ons prior to installing the PV modules 1 Mount the PV modules in the posi ons corresponding to their associated BDM 600 microinverter Each BDM 600 comes with two sets of oppositely sexed DC connectors 2 Connect the posi ve DC wire from the first PV module to the nega vely marked DC connector male pin on the BDM 60...

Page 8: ...nica ng to the BDG 256 Green communica ng to the BDG 256 Status grounding fault The LED light is in solid red color In case of a fault the BDM 600 enters a protec ve mode and stops outputing power The fault message is usually sent to a connected BDG 256 gateway through the power line communica on The error message is then displayed on the screen of BDG 256 gateway by a 16 bit error code The table ...

Page 9: ...talled to reduce the interference to PLC communica on If there are two or more separate BDM systems close by it is highly recommended to install LCF for each micro inverter system to block interference from adjacent other systems 7 If the problem persists please call customer support at NEP WARNING DO NOT ATTEMPT TO REPAIR THE BDM 600 IT CONTAINS NO USER SERVICEABLE PARTS IF TROUBLESHOOTING METHOD...

Page 10: ...ower Grid Frequency Hz 59 3 60 5 Adjustable THD 3 at rated power Power Factor 0 99 at rated power SYSTEM EFFICIENCY CEC Efficiency 95 5 Night Time Tire Loss W 0 11 PROTECTION FUNCTIONS Over Under Voltage Protec on Yes Over Under Frequency Protec on Yes An Islanding Protec on Yes Over Current Protec on Yes Reverse DC Polarity Protec on Yes Overload Protec on Yes Ground Fault Detec on Integrated Prote...

Page 11: ... NEP product specifica ons including high input voltage from generators and lightning strikes c the product if repairs have been done to it other than by NEP or its authorized service centers herea er ASCs d the product if it is used as a component part of a product expressly warranted by another manufacturer e the product if its original iden fica on trade mark serial number markings have been defa...

Page 12: ...or Code s Brief Fault Descrip on and Photos monitoring gateway is required for verifica on Installa on Informa on Modules Used Modules Quan ty Inverters quan ty per string Installa on Company Name Installer Name For the informa on on our warranty terms and condi ons please see our website www northernep com en All fields must be completed in order to process claim Customer Signature Date All rights ...

Page 13: ...12 0011 福岡市博多区博多駅前 3 10 24 藤井ビル 1F TEL 81 092 433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp ...

Reviews: