![Neoway M660 At Command Manual Download Page 18](http://html.mh-extra.com/html/neoway/m660/m660_at-command-manual_1667874018.webp)
Neo_M660 AT Command Set
Copyright © Neoway Technology Co., Ltd
10
2: Query the status
<status>:
0: not active
1: active
<passwd>: Password or code, string type
<classx>:
1: Voice service
2: Data service
4: Fax service
8: SMS
16: Synchronous data service
32: Asynchronous data service
64: Dedicated packet access
128: Dedicated PAD access
Return
Value
when <mode>=2 and command successful:
<CR><LF>+CLCK: <status> [, <class1> [<CR><LF>+CLCK: <status>, <class2>
[...]]<CR><LF>
Example
AT+CLCK="SC",2
+CLCK: 0
OK
AT+CLCK=?
+CLCK:
("PF","SC","AO","OI","OX","AI","IR",
"AB","AG","AC","FD","PN","PU","PP",
"PC")
OK
+CLCK: (list of supported <fac>s)
Remarks
N/A
2.9 Modifying the Password of the PIN: +CPWD
Description
To modify the password of the lock function of the module
Format
AT+CPWD=<fac>,<oldpwd>,<newpwd><CR>
Parameter
<fac>:
"P2": SIM PIN2
"OI": Outgoing international calls
"AI": All incoming calls
"IR": Incoming calls when roaming outside the homing place
"SC": SIM card